AI Article Synopsis

  • The study evaluates the accuracy of computer-guided surgery for immediate dental implant placement using pig hemi-mandibles as a model.
  • Cone-beam computed tomography and virtual models were utilized to plan and simulate the placement of 15 implants, with comparisons made between planned and actual implant positions after surgery.
  • The results indicated that while some measurement variations were found, they were not clinically significant, supporting the use of computer-guided surgery for immediate implants.

Article Abstract

Purpose: Computer-guided surgery has been increased in recent years. Nonetheless, few data are available on the validation of this technique for immediate implant placement. The purpose of this study was to evaluate the accuracy of computer-guided surgery in immediate implant placement.

Materials And Methods: Cone-beam computed tomography scans (CBCTs) and virtual models were obtained of eight fresh pigs hemi-mandibles to perform the digital planning of implants placement. Fifteen implants were simulated, and surgical guides were designed to transfer the digital planning to the surgical procedure. Postsurgical CBCTs were performed to compare the position of the planned implants versus the real implant position. Paired -test and the intra-class correlation coefficient (ICC) were used to assess the mean differences and correlations in each outcome variable evaluated twice by one experienced researcher. Furthermore, variations were compared with the results reported in the scientific literature using a one-sample -test < 0.05.

Results: The measurements of the outcome variables (implants position at the neck and apex level and the angular deviation) showed significant reproducibility (mean difference-0.01 mm, 0.07 mm, and 0.30°, respectively, > 0.05). The ICC values ranged from 0.888 to 0.949. Furthermore, the mean deviation was 1.43 mm at the implant neck, 2.19 mm at the apex, and 6.81° for the angular deviation. Similarly, significant differences ( < 0.05) were found at the neck and angular deviation when comparing the results with values reported in the literature.

Conclusions: Although some variations were observed, they did not have a clinically significant impact. Therefore, computer-guided surgery could be satisfactorily used in immediate implants placement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9118944PMC
http://dx.doi.org/10.4103/jisp.jisp_763_20DOI Listing

Publication Analysis

Top Keywords

computer-guided surgery
12
angular deviation
12
surgery implant
8
implant placement
8
digital planning
8
implants placement
8
implant
5
implants
5
accuracy computer-assisted
4
surgery