Scaling microfluidic throughput with flow-balanced manifolds to simply control devices with multiple inlets and outlets.

Biomicrofluidics

Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, 313 Ferst Drive, Atlanta, Georgia 30332-0535, USA.

Published: May 2022

Microfluidics can bring unique functionalities to cell processing, but the small channel dimensions often limit the throughput for cell processing that prevents scaling necessary for key applications. While processing throughput can be improved by increasing cell concentration or flow rate, an excessive number or velocity of cells can result in device failure. Designing parallel channels can linearly increase the throughput by channel number, but for microfluidic devices with multiple inlets and outlets, the design of the channel architecture with parallel channels can result in intractable numbers of inlets and outlets. We demonstrate an approach to use multiple parallel channels for complex microfluidic designs that uses a second manifold layer to connect three inlets and five outlets per channel in a manner that balances flow properties through each channel. The flow balancing in the individual microfluidic channels was accomplished through a combination of analytical and finite element analysis modeling. Volumetric flow and cell flow velocity were measured in each multiplexed channel to validate these models. We demonstrate eight-channel operation of a label-free mechanical separation device that retains the accuracy of a single channel separation. Using the parallelized device and a model biomechanical cell system for sorting of cells based on their viability, we processed over 16 × 10 cells total over three replicates at a rate of 5.3 × 10 cells per hour. Thus, parallelization of complex microfluidics with a flow-balanced manifold system can enable higher throughput processing with the same number of inlet and outlet channels to control.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9118023PMC
http://dx.doi.org/10.1063/5.0080510DOI Listing

Publication Analysis

Top Keywords

inlets outlets
16
parallel channels
12
devices multiple
8
multiple inlets
8
cell processing
8
channel
7
throughput
5
cell
5
flow
5
channels
5

Similar Publications

Using an acid to stimulate a heterogeneous carbonate reservoir during matrix acidizing may lead to over-treating the high permeability zones, leaving low permeability zones untreated. This is particularly exacerbated in long horizontal sections, necessitating the use of acid diverters for effective acid distribution across the formation. In previous studies, conventional core flooding systems were utilized where single inlet and outlet lines were used or, at best, two outlet lines for dual-core flooding.

View Article and Find Full Text PDF

The current study assesses several water-based PVT system thermal absorber configurations. The thermal absorber in PVT system plays a vital role in efficiency evaluation as it lowers PV temperature and collects heat energy. The current study aims to discover and analyze advanced thermal absorber design by comparing well-received spiral circular absorbers and non-cooled PV with proposed semi-circular thermal absorbers with varying flow configurations.

View Article and Find Full Text PDF

Adaptive Control of Pressure Difference in Abrasive Flow Machining for Inner Hole with High Depth/Diameter Ratio.

Materials (Basel)

December 2024

Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou 310023, China.

To address the issue of uneven pressure distribution in the abrasive flow field within the inner hole of components with a large depth/diameter ratio, an adaptive control strategy for regulating flow field pressure difference is proposed in this paper. The strategy was based on the effects of pressure fluctuations at the abrasive flow inlet and outlet on pressure distribution patterns and pressure changes within the inner hole flow field, as derived from numerical simulations. An adaptive control fixture was also designed, enabling dynamic adjustments to the fixture gap, which significantly reduced the pressure difference in the flow field.

View Article and Find Full Text PDF

Study on performance of perforated dew point indirect : Evaporative coolers.

Sci Rep

January 2025

College of Art and Design, Sichuan Tourism University, No.459, Hongling Road, Longquanyi District, Chengdu City, 610100, Sichuan Province, China.

The Maisotsenko cycle-based coolers have gained increasing attention in recent years due to their advantages of low energy consumption and environmental friendliness. Optimizing the model structure and operating conditions is the primary approach for enhancing the cooling performance of dew-point evaporation systems. In this paper, a novel mathematical model of the perforated dew-point evaporative cooler was developed to investigate its cooling performance.

View Article and Find Full Text PDF

Introduction: Amikacin is sequestered in polyacrylonitrile filters. Methods mitigating sequestration are unknown. Amikacin elimination in a polyacrylonitrile-derived filter preloaded with amikacin was studied in a preliminary study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!