The center coordinate and radius of the spherical hedges are the basic phenotypic features for automatic pruning. A binocular vision-based shape reconstruction and measurement system for front-end vision information gaining are built in this paper. Parallel binocular cameras are used as the detectors. The 2D coordinate sequence of target spherical hedges is obtained by region segmentation and object extraction process. Then, a stereo correcting algorithm is conducted to keep two cameras to be parallel. Also, an improved semi-global block matching (SGBM) algorithm is studied to get a disparity map. According to the disparity map and parallel structure of the binocular vision system, the 3D point cloud of the target is obtained. Based on this, the center coordinate and radius of the spherical hedges can be measured. Laboratory and outdoor tests on shape reconstruction and measurement are conducted. In the detection range of 2,000-2,600 mm, laboratory test shows that the average error and average relative error of standard spherical hedges radius are 1.58 mm and 0.53%, respectively; the average location deviation of the center coordinate of spherical hedges is 15.92 mm. The outdoor test shows that the average error and average relative error of spherical hedges radius by the proposed system are 4.02 mm and 0.44%, respectively; the average location deviation of the center coordinate of spherical hedges is 18.29 mm. This study provides important technical support for phenotypic feature detection in the study of automatic trimming.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9114885 | PMC |
http://dx.doi.org/10.3389/fpls.2022.849821 | DOI Listing |
Plant Dis
August 2022
Nanyang Normal University, Nanyang, China;
Front Plant Sci
May 2022
Research Center of Intelligent Equipment, Beijing Academy of Agriculture and Forestry Sciences, Beijing, China.
The center coordinate and radius of the spherical hedges are the basic phenotypic features for automatic pruning. A binocular vision-based shape reconstruction and measurement system for front-end vision information gaining are built in this paper. Parallel binocular cameras are used as the detectors.
View Article and Find Full Text PDFPLoS One
August 2020
Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan.
Background: High myopia is a sight-threatening disease that causes axial length elongation and severe complications. Data on the benefits of posterior scleral reinforcement surgery in myopia control have been conflicting. The purpose of this study was to explore the treatment effect and complications of posterior scleral reinforcement in the treatment of myopia.
View Article and Find Full Text PDFJ Cataract Refract Surg
May 2015
From the Mannheim Institute of Public Health (Schuster, Vossmerbaeumer), Social and Preventive Medicine, Medical Faculty Mannheim, University of Heidelberg, and the Department of General Internal Medicine and Psychosomatics (Tesarz), Medical Hospital, University of Heidelberg, Heidelberg, and the Department of Ophthalmology (Schuster, Vossmerbaeumer), Mainz Medical Center, University of Mainz, Mainz, Germany.
This review was conducted to compare the physical effect of aspheric IOL implantation on wavefront properties with that of spherical IOL implantation. The peer-reviewed literature was systematically searched in Medline, Embase, Web of Science, Biosis, and the Cochrane Library according to the Cochrane Collaboration method. Inclusion criteria were randomized controlled trials comparing the use of aspheric versus spherical monofocal IOL implantation that assessed visual acuity, contrast sensitivity, or quality of vision.
View Article and Find Full Text PDFOphthalmology
November 2013
Mannheim Institute for Public Health, Social and Preventive Medicine, Medical Faculty Mannheim, University of Heidelberg, Heidelberg, Germany; Medical Physics, Mannheim Medical School, University of Heidelberg, Heidelberg, Germany. Electronic address:
Purpose: To provide a summary of the impact on vision of an aspheric intraocular lens (IOL) compared with a spherical IOL in cataract surgery.
Design: Systematic review with meta-analysis.
Participants: Patients from published randomized controlled trials (RCTs) of cataract surgery with aspheric compared with spherical monofocal IOL implantation.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!