Objective: In this study, autologous bone grafts using bone-fixing nails made of magnesium-zinc-calcium ternary alloys were performed using rabbit skulls.

Material And Methods: Two types of nails for bone fixation were prepared: 2.5 mm width, 3 mm length and 2.5 mm width, 2 mm length. A disk-shaped bone with a diameter of 5 mm was resected from the parietal bone and fixed with a 3 mm long nail. As a control group, a 2 mm long nail was driven into the existing bone. The rabbits were sacrificed at 1, 4, 12, and 24 weeks after surgery. The resected samples were observed with micro X-ray CT, and embedded in methyl methacrylate to prepare non-decalcified specimens. The in vivo localization of elements was examined using energy-dispersive X-ray spectroscopy (EDS).

Results: Micro X-ray CT images of samples showed volume reduction due to degradation in both the bone graft and control groups. No significant difference in the amount of degradation between the two groups was observed, however characteristic degradation processes were observed in each group. The samples stained with alizarin red S showed amorphous areas around the nails, which were considered as corrosion products and contacted directly with the newly formed bones. EDS analysis showed that corrosion products were mainly composed of magnesium and oxygen at an early stage, while calcium and phosphorus were detected on the surface layer during the long-term observation.

Conclusions: The degradation speed of the magnesium alloy nails varied depending on the shapes of the nails and surrounding tissue conditions. A calcium phosphate layer was formed on the surface of magnesium alloy nails, suggesting that the degradation rate of the nail was slow.

Download full-text PDF

Source
http://dx.doi.org/10.1177/22808000221095230DOI Listing

Publication Analysis

Top Keywords

alloy nails
12
autologous bone
8
bone grafts
8
25 mm width
8
long nail
8
micro x-ray
8
corrosion products
8
magnesium alloy
8
nails
7
bone
7

Similar Publications

In addition to the basic and main parts of hospital equipment, 316 L stainless steel is widely utilized in futures such as nails and screws, wires and medical bone clips, dental implants, heart springs (stents), needles, surgical scissors, etc. In the present study, the electrophoretic deposition of a composite based on chitosan (CS), gelatin, nano and microparticles of hydroxyapatite on a 316 L stainless steel substrate was investigated. Hydroxyapatite particles are added to it due to the ossification abilities of steel and due to an enhanced adhesion and bone production, CS and biocompatible gelatin polymer particles were also added to hydroxyapatite.

View Article and Find Full Text PDF

Orthopedic implants such as arthroplasty prostheses, fracture plates, and intramedullary nails often use materials like Ti6Al4V alloy and commercially pure titanium (CP-Ti), which have Young's modulus significantly higher than that of human cortical bone, potentially causing stress shielding and inhibiting effective fracture healing. TiNbSn alloy, a β-type titanium alloy with a lower Young's modulus (40-49 GPa), has shown promise in reducing stress shielding and enhancing bone healing by promoting effective load sharing with bone. This study used 5-hole plates made from TiNbSn alloy and CP-Ti to investigate their effects on bone healing in a rat femoral fracture model.

View Article and Find Full Text PDF

The most problematic complication of external fixation is infection at the pin insertion site. Technology that improves the adhesion of the external fixation pin to the skin, subcutaneous tissue, and bone may prevent infection at the pin site. The purpose of this study is to formulate a calcium phosphate-fibroblast growth factor (Cp-FGF) coating on a stainless-steel external fixation pin and to verify its effectiveness in reducing infection at the pin site and its possible influence on bone fixation in animal experiments.

View Article and Find Full Text PDF
Article Synopsis
  • - This article discusses the potential of metallic glasses, which have unique structures lacking defects, making them strong, tough, and corrosion-resistant, for biomedical applications like implants.
  • - It highlights how Ti-based metallic glasses are used for durable implants like bone plates, while Mg-based types are favored for biodegradable options like stents due to their ability to degrade in the body.
  • - The article identifies challenges such as the stiffness of Ti-based glasses and rapid degradation of Mg-based glasses, suggesting solutions like introducing porous structures, improving surface bioactivity, and enhancing corrosion resistance to advance their use in medicine.
View Article and Find Full Text PDF

Background: The retention of foreign bodies inside the body during ludic/sexual procedures or for traumatism represents one of the causes of visits to accident and emergency departments that often requires surgical removal of the foreign body. However, there are cases where the discovery of such foreign bodies takes place after many years, as in patients that are slightly compromised from a neuro-sociological point of view.

Case Presentation: A 76-year-old male presented to an outpatient urological examination due to an increase in scrotal volume.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!