Wearable ankle-foot orthoses (AFO) are widely prescribed clinically; however, their effect on balance control during ramp ascent/descent walk remains unknown. This study evaluates walking stability on a ramp during weight loading and unloading transitions of the stance phase with the effect of an adjustable AFO. An AFO is tuned firstly by tuning dorsiflexion only and then combining dorsi-plantarflexion adjustments. Gait stability is assessed from neuromotor input (centre-of-mass) and output (centre-of-pressure) responses obtained through motion-capture system and force platform. Stability margins are quantified from Nyquist and Bode methods illustrating the loading phase as stable and the unloading phase as unstable transition in all walking conditions. Further, a significant decrease in stability (p < 0.05) is observed by wearing AFO in its free mode which gets improved (p < 0.05) by tuning AFO. Results from neuromotor outputs also illustrated a strong interlimb correlation (p < 0.001), which implies a compensatory interaction between opposite limbs loading and unloading transitions. Neuromotor inputs illustrated unstable responses both in loading and unloading transitions and were observed to be greater in magnitudes compared with output margins. The overall results support the hypothesis that a wearable AFO affects gait stability during transitional phases, and by applying AFO adjustments, neuromotor balance control achieves stability margins closer to normal range.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11517-022-02587-zDOI Listing

Publication Analysis

Top Keywords

stability ramp
8
ramp ascent/descent
8
stability
5
evaluation ankle-foot
4
ankle-foot orthosis
4
orthosis gait
4
gait transitional
4
transitional stability
4
ascent/descent wearable
4
wearable ankle-foot
4

Similar Publications

Medial Meniscus Ramp Tears: State of the Art.

J ISAKOS

December 2024

Twin Cities Orthopedics, Edina, Minnesota, USA. Electronic address:

Medial meniscus ramp tears are tears of the posteromedial capsule or peripheral rim of the posteromedial meniscus that frequently occur with anterior cruciate ligament (ACL) tears. The incidence and prevalence of medial meniscus ramp tears has been increasing in the recent literature due to the increased understanding of the anatomy and diagnosis of these tears. When a patient presents with an ACL tear, a medial meniscus ramp tear should be suspected if the patient has a grade 3+ Lachman or pivot shift exam, a vertical line of increased signal intensity in the posterior capsule or peripheral meniscus on magnetic resonance imagining (MRI), or posteromedial tibial plateau bone bruising on MRI.

View Article and Find Full Text PDF

The effects of 5.8-GHz microwave (MW) irradiation on the synthesis of mesoporous selenium nanoparticles (mSeNPs) in aqueous medium by reduction of selenite ions with ascorbic acid, using zinc nanoparticles as a hard template and cetyltrimethylammonium bromide (CTAB) as a micellar template, are examined for the first time with a particular emphasis on MW-particle interactions and the NPs morphology. This MW-assisted synthesis is compared to 2.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate the biomechanical properties of SutureTape as an alternative technique for arthrodesis of the metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joint arthrodesis when compared with surgical steel wire.

Methods: A total of 32 fingers (index, long, ring, and small) from two matched pair cadaveric hands were used. K-wire and surgical steel wire were used for MCP and PIP joint arthrodesis of the control group (group I), whereas K-wire and SutureTape were used for the experimental group (group II).

View Article and Find Full Text PDF

Revolutionizing cesium monitoring in seawater through electrochemical voltammetry and machine learning.

J Hazard Mater

November 2024

School of Civil, Environmental, and Architectural Engineering, Korea University, Seoul 02841, Republic of Korea. Electronic address:

Monitoring radioactive cesium ions (Cs) in seawater is vital for environmental safety but remains challenging due to limitations in the accessibility, stability, and selectivity of traditional methods. This study presents an innovative approach that combines electrochemical voltammetry using nickel hexacyanoferrate (NiHCF) thin-film electrode with machine learning (ML) to enable accurate and portable detection of Cs. Optimizing the fabrication of NiHCF thin-film electrodes enabled the development of a robust sensor that generates cyclic voltammograms (CVs) sensitive to Cs⁺ concentrations as low as 1 ppb in synthetic seawater and 10 ppb in real seawater, with subtle changes in CV patterns caused by trace Cs⁺ effectively identified and analyzed using ML.

View Article and Find Full Text PDF

The Environmental Economic Power Dispatch (EEPD) problem, a widely studied bi-objective nonlinear optimization challenge in power systems, traditionally focuses on the economic dispatch of thermal generators without considering network security constraints. However, environmental sustainability necessitates reducing emissions and increasing the penetration of renewable energy sources (RES) into the electrical grid. The integration of high levels of RES, such as wind and solar PV, introduces stability issues due to their uncertain and intermittent nature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!