Aim: The present study aimed to assess the antimicrobial efficacy of hematoporphyrin derivative, sodium hypochlorite (NaOCl), glutaraldehyde (GaH), and a chlorhexidine (CHX) on mass loss (ML), microhardness, and surface roughness (Ra) of acrylic denture base colonized with C. Albicans.
Material And Methods: A total of 40 heat cure acrylic resin dentures were fabricated and inoculated by the American Type Culture Collection (ATCC) of C. Albicans in an in-vitro situation. Specimens were divided into four groups (n = 10) based on the method of disinfection. Hematoporphyrin derivatives, 1% NaOCl, 2% GaH, and 4% CHX.The pre and post candida (CFU/ml) counts were recorded before and after immersion. ML, microhardness, and Ra of acrylic denture were also assessed. Statistical analysis was executed for CFU/mL (log10) for exposed C. Albicans by two-way ANOVA and Tukey's multiple tests (p > 0.05). For normality of the data, Dunnet's Simultaneous test was performed.
Results: In terms of candida strain analysis, pretreatment to posttreatment comparisons revealed a reduction in mean Candida count in all groups (p < 0.05). The highest ML value after post candida disinfection of acrylic denture was observed in 2% GaH (1.587 ± 0.25) treated specimens. The least microhardness value was found in group 1 when treated with hematoporphyrin (0.97 ± 0.22 VHN) which was significantly different from other groups (p < 0.05). Group 1 surface treated with hematoporphyrin derivate (1.84 ± 0.22 μm) showed the highest Ra values (p < 0.05).
Conclusion: Acrylic denture base resin colonized with C. Albicans when treated with a chemical disinfectant of 4% chlorhexidine displayed the highest antimicrobial efficacy with reduced mass loss, less surface roughness, and maximum denture hardness.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.pdpdt.2022.102911 | DOI Listing |
J Prosthodont
January 2025
Department of Community Medicine and Health Care, University of Connecticut Health Center, Farmington, Connecticut, USA.
Purpose: The primary objective of this retrospective study was to evaluate the survival outcomes of immediately loaded acrylic resin complete arch fixed implant-supported prosthesis (CAFIP) fabricated from the denture conversion protocol. The secondary objective was to evaluate the early implant survival outcomes associated with these prostheses.
Material And Methods: A retrospective chart review was conducted to study the clinical outcomes data of immediately loaded conversion prostheses and immediately loaded implants.
J Prosthet Dent
January 2025
Professor, Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, SC, Brazil. Electronic address:
Statement Of Problem: Staining at the gingival margin could impact denture longevity, but the behavior of gingival colored composite resins (GCCs) in this area remains unclear.
Purpose: This in vitro study evaluated surface staining, microleakage, and push-out bond strength at the gingival margin of artificial teeth, comparing two consistencies of GCCs with two resin base materials.
Material And Methods: Specimens included artificial teeth (Ivostar; Ivoclar AG) and two acrylic resin base materials: conventional (Ondacryl; Clássico) and high-impact (Diamond D; Keystone Industries) (n=300).
Cureus
December 2024
Anatomy, Universiti Sains Islam Malaysia, Kuala Lumpur, MYS.
Background Dentures are one of the main treatments dentists deliver to restore the oral function and aesthetics of individuals with missing teeth. Clinical denture fabrication and manufacturing is one of the main training modules for undergraduates during dental clinical training. However, students often face problems during denture delivery due to multiple factors causing discomfort to patients, affecting the quality of the denture and the patient's adaptation period to the denture.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
Department of Dentistry, Federal University of Santa Catarina (UFSC), Av. Delsino Conti, s/n-Trindade, Florianópolis 88040-900, SC, Brazil.
This study aimed to evaluate the antimicrobial effectiveness of different disinfection protocols for dentures by combining methods, varying intervention sequences, sodium hypochlorite (NaOCl) concentrations (0.1% and 0.25%), and post-exposure to intraoral temperature.
View Article and Find Full Text PDFJ Contemp Dent Pract
September 2024
Graduate Program in Dentistry, Federal University of Pelotas, Pelotas, Rio Grande do Sul, Brazil; Department of Dentistry, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, The Netherlands, ORCID: https://orcid.org/0000-0002-5166-8233.
Aim: This study aimed to assess if the addition of origanum oil to denture materials could decrease microorganisms counts and biofilm formation without changing their mechanical/surface properties.
Materials And Methods: A total of 66 resilient denture liner discs (SoftConfort, Dencril Comércio de Plásticos Ltda, SP, Brazil) were prepared with fixed dimensions of 10 × 3 mm for biofilm assay ( = 36) and 12 × 2 mm for sorption-solubility tests ( = 30) containing three oil concentrations - 0, 2.5 and 5%, thereby = 12 per each group samples for biofilm assay and = 10 per each group for sorption-solubility test respectively.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!