A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrophysiological Assessment in Birdshot Chorioretinopathy: Flicker Electroretinograms Recorded With a Handheld Device. | LitMetric

Purpose: The flicker electroretinogram (ERG) is a sensitive indicator of retinal dysfunction in birdshot chorioretinopathy (BCR). We explored recordings from a handheld device in BCR, comparing these with conventional recordings in the same patients and with handheld ERGs from healthy individuals.

Methods: Non-mydriatic flicker ERGs, using the handheld RETeval system (LKC Technologies), were recorded with skin electrodes at two centers. At one center (group 1), the stimuli (85 Td·s, 850 Td background) delivered retinal illuminance equivalent to international standards; at the other center (group 2), a different protocol was used (32 Td·s, no background). Patients also underwent international standard flicker ERG recordings with conventional electrodes following mydriasis. Portable ERGs from patients were also compared with those from healthy individuals.

Results: Thirty-two patients with BCR (mean age ± SD, 56.4 ± 11.3 years) underwent recordings. Portable and standard ERG parameters correlated strongly (r > 0.75, P < 0.01) in both groups. Limits of agreement for peak times were tighter in group 1 (n = 21; -4.3 to +2.0 ms [right eyes], -3.9 to 1.5 ms [left eyes]) than in group 2 (n = 11; -3.4 to +6.9 ms [right eyes], -4.8 to +9.0 ms [left eyes]). Compared with healthy controls (n = 66 and n = 90 for groups 1 and 2, respectively), patients with BCR showed smaller mean amplitudes and longer peak times.

Conclusions: Portable ERGs correlated strongly with conventional recordings, suggesting potential in rapid assessment of cone system function in office settings.

Translational Relevance: Flicker ERGs, known to be useful in BCR, can be obtained rapidly with a portable device with skin electrodes and natural pupils.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9145202PMC
http://dx.doi.org/10.1167/tvst.11.5.23DOI Listing

Publication Analysis

Top Keywords

birdshot chorioretinopathy
8
handheld device
8
conventional recordings
8
flicker ergs
8
skin electrodes
8
center group
8
portable ergs
8
compared healthy
8
patients bcr
8
[right eyes]
8