Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To estimate organs' absorbed dose from the two-phase CT of parathyroid glands, effective dose (ED) based on three different methods, and compare the dose values with those reported by other published protocols.
Methods: Volumetric-computed-tomography-dose-index (CTDI), dose-length-product (DLP), and the corresponding scan length during each phase of a parathyroid protocol were recorded, for seventy-six patients. One k-factor, and two different k-factors for the neck and chest area were used to estimate the ED from DLP. A Monte Carlo software, VirtualDoseCT, was also used for the estimation of organs' absorbed dose and ED.
Results: Two-phase parathyroid CT resulted in a mean ED of 3.93 mSv, 4.29 mSv and 4.21 mSv according to the one k-factor, two k-factors, and VirtualDoseCT methods, respectively. The two k-factors method resulted in a slight overestimation of 1.9% in total ED compared to VirtualDoseCT. No statistically significant difference was found in ED values between these methods (Wilcoxon test, p > 0.05), except for female patients in the pre-contrast phase. The organs inside the scanning field of view (SFOV) received the following doses: thymus 23.3 mGy, lungs 11.5 mGy, oesophagus 9.2 mGy, thyroid 6.9 mGy, and breast 6.3 mGy. The ED and organs' dose (OD) values were significantly lower in the pre-contrast than in the arterial phase (Wilcoxon test, p < 0.001). A statistically significant difference was observed between male and female patients for the pre-contrast phase (Mann-Whitney test, p < 0.05), regarding the ED values obtained with the two k-factors method and VirtualDoseCT software.
Conclusions: The two k-factors method could be applied for the ED estimation in clinical practice, if appropriate software is not available. An extensive range of ED values derived from the literature, mainly depending on the acquisition protocol parameters and the estimation method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/2057-1976/ac7169 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!