In recent decades, robot-assisted surgery has been proven superior at providing more accurate outcomes than the conventional one, particularly in minimally invasive procedures. However, there are still limitations to these kinds of surgical robots. Accurate bone drilling on the steep and hard surface of cortical bone is still challenging. The issues of slipping away from the target entry point on the bone surface and subsequently deviating from the desired path are still not completely solved. Therefore, in this paper, a force control is proposed to accompany the resolved motion rate controller in a handheld orthopedic robot system. The force control makes it possible to adjust the contact compliance of the drill to the bone surface. With the proper contact compliance, the drill can be prevented from deflecting in contact with the bone surface, and will eventually be directed to the target entry point. The experiments on test jig and vertebra phantom also show that the robot under the proposed contact compliance visual feedback control structure could produce better usability positioning accuracy under various contact disturbances than its counterpart.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9103330PMC
http://dx.doi.org/10.3390/s22093205DOI Listing

Publication Analysis

Top Keywords

contact compliance
16
bone surface
12
visual feedback
8
bone drilling
8
target entry
8
entry point
8
force control
8
compliance drill
8
contact
6
bone
6

Similar Publications

Self-emulsifying drug delivery systems (SEDDS) represent an innovative approach to improving the solubility and bioavailability of poorly water-soluble drugs, addressing significant challenges associated with oral drug delivery. This review highlights the advancements and applications of SEDDS, including their transition from liquid to solid forms, while addressing the formulation strategies, characterization techniques, and future prospects in pharmaceutical sciences. The review systematically analyzes existing studies on SEDDS, focusing on their classification into liquid and solid forms and their preparation methods, including spray drying, hot-melt extrusion, and adsorption onto carriers.

View Article and Find Full Text PDF

Personalised nutrition (PN) as a new endeavour emerged in the background of the human genome project with the ease to analyse genetic heterogeneity. First commercial offers with recommendations for diet and lifestyle changes, usually based on a few polymorphisms, entered markets soon after the presentation of the human genome blueprint. Although PN has seen many attempts, meanwhile, with the inclusion of other biomedical measures such as microbiome and/or continuous glucose monitoring, scientific assessments of such approaches in various settings revealed limited success.

View Article and Find Full Text PDF

Macrophage metabolism is closely linked to their phenotype and function, which is why there is growing interest in studying the metabolic reprogramming of macrophages. Bioactive glass (BG) S53P4 is a bioactive material used especially in bone applications. Additionally, BG S53P4 has been shown to affect macrophages, but the mechanisms through which the possible immunomodulatory effects are conveyed remain unclear.

View Article and Find Full Text PDF

: Mothers and their newborns experiencing caesarean birth often receive delayed or interrupted skin-to-skin care (SSC) despite the intervention being well recognised as beneficial to both mother and baby, with no associated risk for increased morbidity or mortality. Maternal birth satisfaction is recognised as an indicator of quality maternity care; however, most of the research has focused on early intraoperative SSC initiation and breastfeeding outcomes. : To collate and synthesise evidence for maternal satisfaction of intraoperative and early postpartum SSC during and immediately following caesarean birth.

View Article and Find Full Text PDF

Consensus-Based Guidelines for Best Practices in the Selection and Use of Examination Gloves in Healthcare Settings.

Nurs Rep

January 2025

Escola Enfermagem (Porto), Faculdade Ciências da Saúde e Enfermagem, Universidade Católica Portuguesa, 4169-005 Porto, Portugal.

Background/objectives: Healthcare-associated infections (HAIs) and antimicrobial resistance (AMR) present significant challenges in modern healthcare, leading to increased morbidity, mortality, and healthcare costs. Examination gloves play a critical role in infection prevention by serving as a barrier to reduce the risk of cross-contamination between healthcare workers and patients. This manuscript aims to provide consensus-based guidelines for the optimal selection, use, and disposal of examination gloves in healthcare settings, addressing both infection prevention and environmental sustainability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!