A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Two near-infrared fluorescent probes based on dicyanoisfluorone for rapid monitoring of Znand Pb. | LitMetric

Two near-infrared fluorescent probes based on dicyanoisfluorone for rapid monitoring of Znand Pb.

Methods Appl Fluoresc

College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, Guangxi 541006, People's Republic of China.

Published: May 2022

Zinc (Zn) and lead (Pb) ions in the environment have important effects on human health and environmental safety. Therefore, it is necessary to effectively detect them by a convenient and reliable analysis method. In this study, two near-infrared fluorescent probes for the fast determination of Znand Pbwere synthesized by a simple Schiff base reaction between the dicyanoisophorone skeleton and carbohydrazide derivatives. Among them, the probe with the thiophene-2-carbohydrazide group showed a selective fluorescence response to Znand Pbwith a maximum emission wavelength of 670 nm. And the detection limits of the probe for Znand Pbwere 1.59 nM and 1.65 nM, respectively. In contrast the probe modified by the furan-2-carbohydrazide group achieved quantitative detection of Zn, with a detection limit of 2.7 nM. These results were attributed to the fact that the probes bind to Znand Pbin stoichiometric ratios of 1:1, blocking the intramolecular PET effect. Furthermore, these two probes can be recycled through the action of EDTA and have been successfully used to detect Znand Pbin real water samples.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2050-6120/ac7199DOI Listing

Publication Analysis

Top Keywords

near-infrared fluorescent
8
fluorescent probes
8
znand pbwere
8
znand pbin
8
znand
6
probes
4
probes based
4
based dicyanoisfluorone
4
dicyanoisfluorone rapid
4
rapid monitoring
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!