Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The T-lymphocyte-mediated inflammation in Crohn's disease can be assessed by quantifying CD3-positive T-lymphocyte counts in colonic sections. We developed and validated a process to reliably quantify immunohistochemical marker-positive cells in a high-throughput setting using whole slide images (WSIs) of CD3-immunostained colonic and ileal tissue sections. In regions of interest (ROIs) and/or whole tissue sections of 40 WSIs from 36 patients with Crohn's disease, CD3-positive cells were quantified by an expert gastrointestinal pathologist (gold standard) and by image analysis algorithms developed with software from 3 independent vendors. Semiautomated quantification of CD3-positive cell counts estimated in 1 ROI per section were accurate when compared with manual analysis (Pearson correlation coefficient, 0.877 to 0.925). Biological variability was acceptable in digitally determined CD3-positive cell measures between 2 to 5 ROIs annotated on the same tissue section (coefficient of variation <25%). Results from computer-aided analysis of CD3-positive T lymphocytes in a whole tissue section and the average of results from 2 to 5 ROIs per tissue section lacked reliability (overestimation or underestimation and systematic bias), suggesting that absolute quantification of CD3-positive T lymphocytes in a whole tissue section may be more accurate. Semiautomated image analysis in WSIs demonstrated reproducible CD3-positive cell measures across 3 independent algorithms. A computer-aided digital image analysis method was developed and validated to quantify CD3-positive T lymphocytes in colonic and ileal biopsy sections from patients with Crohn's disease. Results support consideration of this digital analysis method for use in future Crohn's disease clinical studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/PAI.0000000000001035 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!