A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Medication-Facilitated Advanced Airway Management with First-Line Use of a Supraglottic Device - A One-Year Quality Assurance Review. | LitMetric

Introduction: Airway management is a controversial topic in modern Emergency Medical Services (EMS) systems. Among many concerns regarding endotracheal intubation (ETI), unrecognized esophageal intubation and observations of unfavorable neurologic outcomes in some studies raise the question of whether alternative airway techniques should be first-line in EMS airway management protocols. Supraglottic airway devices (SADs) are simpler to use, provide reliable oxygenation and ventilation, and may thus be an alternative first-line airway device for paramedics. In 2019, Alachua County Fire Rescue (ACFR; Alachua, Florida USA) introduced a novel protocol for advanced airway management emphasizing first-line use of a second-generation SAD (i-gel) for patients requiring medication-facilitated airway management (referred to as "rapid sequence airway" [RSA] protocol).

Study Objective: This was a one-year quality assurance review of care provided under the RSA protocol looking at compliance and first-pass success rate of first-line SAD use.

Methods: Records were obtained from the agency's electronic medical record (EMR), searching for the use of the RSA protocol, advanced airway devices, or either ketamine or rocuronium. If available, hospital follow-up data regarding patient condition and emergency department (ED) airway exchange were obtained.

Results: During the first year, 33 advanced airway attempts were made under the protocol by 23 paramedics. Overall, compliance with the airway device sequence as specified in the protocol was 72.7%. When ETI was non-compliantly used as first-line airway device, the first-pass success rate was 44.4% compared to 87.5% with adherence to first-line SAD use. All prehospital SADs were exchanged in the ED in a delayed fashion and almost exclusively per physician preference alone. In no case was the SAD exchanged for suspected dislodgement evidenced by lack of capnography.

Conclusion: First-line use of a SAD was associated with a high first-pass attempt success rate in a real-life cohort of prehospital advanced airway encounters. No SAD required emergent exchange upon hospital arrival.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9280059PMC
http://dx.doi.org/10.1017/S1049023X22000802DOI Listing

Publication Analysis

Top Keywords

advanced airway
20
airway management
20
airway
14
airway device
12
success rate
12
first-line sad
12
first-line
8
one-year quality
8
quality assurance
8
assurance review
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!