Objective: To determine whether reformatted computed tomography (CT) scans would increase surgeons' confidence in placing a trans sacral (TS) screw in the first sacral segment.
Setting: Level 1 trauma center.
Design: A retrospective cohort study.
Patients/participants: There were 50 patients with uninjured pelvises who were reviewed by 9 orthopaedic trauma fellowship-trained surgeons and 5 orthopaedic residents.
Main Outcome Measurements: The overall percentage of surgeons who believe it was safe to place a TS screw in the first sacral segment with standard (axial cuts perpendicular to the scanner gantry) versus reformatted (parallel to the S1 end plate) CT scans.
Results: Overall, 58% of patients were believed to have a safe corridor in traditional cut axial CT scans, whereas 68% were believed to have a safe corridor on reformatted CT scans ( P < 0.001). When grouped by dysplasia, those without sacral dysplasia (n = 28) had a safe corridor 93% of the time on traditional scans and 93% of the time with reformatted CT scans ( P = 0.87). However, of those who had dysplasia (n = 22), only 12% were believed to have a safe corridor on original scans compared with 35% on reformatted scans ( P < 0.001).
Conclusions: CT scan reformatting parallel to the S1 superior end plate increases the likelihood of identifying a safe corridor for a TS screw, especially in patients with evidence of sacral dysplasia. The authors would recommend the routine use of reformatting CT scans in this manner to provide a better understanding of the upper sacral segment osseous fixation pathways.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BOT.0000000000002414 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!