Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Xpert Xpress SARS-CoV-2/Flu/RSV is a rapid diagnostic test currently approved for the detection of SARS-CoV-2 using upper respiratory tract specimens. This study attempts to assess the performance of this assay using upper and lower respiratory tract specimens by comparing its results to the lab-developed PCR test. We assessed the performance of GeneXpert for the detection of SARS-CoV-2, influenza A, influenza B, and respiratory syncytial virus for upper respiratory tract specimens. In addition, the SARS-CoV-2 detection was evaluated for lower respiratory tract specimens (bronchoalveolar lavage and tracheal aspirate). Precision and reproducibility of the test were also assessed using samples with varying cycle threshold values. Xpert Xpress SARS-CoV-2/Flu/RSV shows 100% positive and negative agreements for all four targets when tested using upper respiratory tract specimens. For lower respiratory tract specimens, tracheal aspirate and bronchoalveolar lavage samples respectively show 96% and 100% positive percent agreement for SARS-Cov-2 target only. No positive flu/RSV samples were included for lower respiratory tract specimens. Both samples show 100% negative percent agreement. The precision and reproducibility assay also showed 100% correspondence. Xpert Xpress SARS-CoV-2/Flu/RSV can be potentially used for SARS-Cov-2 detection in lower respiratory tract specimens. Performance passed our study acceptance criteria and shows promising implications as a point of care detection assay. Cepheid's Xpert Xpress SARS-CoV-2/Flu/RSV provides a means of rapid diagnosis that can help in hospital bed management and patient flow. It is also important for each microbiology lab to increase its capacity and most importantly have a different platform to overcome the anticipated reagent shortage at times of peak community transmission. There is limited evidence on using it for lower respiratory tract specimens. Here we present our validation for upper respiratory tract specimens as well as a potential use for lower respiratory specimens (BAL and TA), and we discuss some of the applications we have been using in our organization.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9241901 | PMC |
http://dx.doi.org/10.1128/spectrum.00399-22 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!