Background: Short peripheral intravenous catheters are the most common invasive procedure used to deliver medications, blood products, and fluids to patients, and failure has the potential to impact the quality of care.

Methods: This study compared IVs stabilized with current transparent film dressing to those using an engineered stabilization device. The first phase of the study evaluated documentation; data from patient records were found less than optimal but most complete for securement and removal, the two fields most critical to the study. The second phase measured IV dwell time, restart rates, and time between IV loss and restarts.

Results: Although there were no statistically significant differences in restarts, the IV dwell time was longer when the engineered device was in place, helping to extend the life of the IV and prevent interruption of care. In the absence of data on the cost of infections and other complications, the use of an engineered device increased the cost of IV starts.

Conclusions: Adding an engineered stabilization device increases the cost of peripheral IV starts, but contributes to reducing IV restarts and preventing IV complications due to destabilized IVs. Although there were no statistically significant differences in restarts, the IV dwell time was longer when the device was in place, helping to extend the life of the IV and prevent interruption of care. Complete and accurate documentation and improved quality depended upon the ability to abstract unit-level data, which is vital for capturing the appropriate healthcare indicators. Clinical nurses must be involved in the decision-making regarding health records and operability at the unit level.

Download full-text PDF

Source
http://dx.doi.org/10.1177/11297298221098331DOI Listing

Publication Analysis

Top Keywords

stabilization device
12
dwell time
12
peripheral intravenous
8
engineered stabilization
8
statistically differences
8
differences restarts
8
restarts dwell
8
time longer
8
engineered device
8
device place
8

Similar Publications

Machine learning algorithms have proven to be effective for essential quantum computation tasks such as quantum error correction and quantum control. Efficient hardware implementation of these algorithms at cryogenic temperatures is essential. Here we utilize magnetic topological insulators as memristors (termed magnetic topological memristors) and introduce a cryogenic in-memory computing scheme based on the coexistence of a chiral edge state and a topological surface state.

View Article and Find Full Text PDF

Intermetallic Layers with Tuned Na Nucleation and Transport for Anode-Free Sodium Metal Batteries.

Nano Lett

January 2025

Department of Applied Physics and Research Institute for Advanced Manufacturing, The Hong Kong Polytechnic University, Hung Hom, Hong Kong 999077, China.

Sodium metal batteries without pre-deposited Na (anode-free) and with a limited amount of Na metal (anode-less) have attracted increasing attention due to their competitive energy density and the high abundance of sodium. However, severe interfacial issues result in poor cycling stability and low Coulombic efficiency. Here, the lightweight interphase layers composed of intermetallic nanoparticles (Sn-Cu and Sn-Ni) are applied to improve Na plating/stripping behaviors.

View Article and Find Full Text PDF

This study presents a novel optoporation technique using a titanium-coated TiO microstructure (TMS) device activated by an infrared diode laser for highly efficient intracellular delivery. The TMS device, fabricated with 120 nm titanium coating on a titanium dioxide (TiO) microstructure containing microneedles (height ∼2 μm and width ∼4.5 μm), demonstrates enhanced biocompatibility and thermal conductivity compared to the conventional TiO microstructure (MS).

View Article and Find Full Text PDF

Flexible and Durable Conducting Fabric Electrodes for Next-Generation Wearable Supercapacitors.

ACS Appl Mater Interfaces

January 2025

Department of Physics, School of Electrical and Electronics Engineering, SASTRA Deemed to be University, Thanjavur 613 401, Tamil Nadu, India.

This study presents the fabrication of highly conducting Au fabric electrodes using a layer-by-layer (LBL) approach and its application toward energy storage. Through the ligand-exchange mechanism, the alternating layers of tris(2-aminoethyl)amine (TREN) and gold nanoparticles (Au NPs) encapsulated with tetraoctylammonium bromide (TOABr) ligands (Au-TOABr) were deposited onto the fabric to achieve a highly conducting Au fabric (0.12 Ω/□) at room temperature in just two LBL cycles.

View Article and Find Full Text PDF

Evaluation of frictional wear in a follow-up screw-rod kinematic node in GGS transpedicular stabilization.

Acta Bioeng Biomech

September 2024

Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Wrocław, Poland.

: The aim of this study was to evaluate the abrasive wear of the sliding screw-rod joint used in growth guidance system (GGS) stabilizers, allowing for the translation of the screw along the rod during the spinal growth process in a standard and modified system. : The study used single kinematic screw-rod pairs made of titanium alloy Ti6Al4V. Mechanical tests (cyclic loads) simulated the stabilizer's operation under conditions similar to actual use.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!