Background: Current literature identifies mobile phones of staff as potential vectors for hospital-acquired infection.

Methods: A pre-post, quasi-experimental study was conducted in a 20 bed intensive care unit (ICU). Surface bioburden of personal and shared mobile phones was estimated with a luminometer, expressed in Relative Light Units (RLU). Effects of a simple sanitizing wipe-based disinfection routine were measured at baseline, and at 1, 3, 6, and 12 months after implementation of the disinfection routine.

Results: Personal mobile phones and shared phones of 30 on-shift ICU nurses were analyzed at each collection. RLUs for personal phones decreased from baseline to 12 months post-intervention (Geometric mean 497.1 vs 63.36 RLU; adj P < .001), while shared unit phones also demonstrated a decrease from baseline to 12 months post-intervention (Geometric mean 417.4 vs 45.90 RLU; adj P < .001).

Discussion: No recommended practice yet exists for disinfection of mobile phones in the acute care setting. The disinfection method and routine used in this study may have implications for use in acute care settings to reduce opportunities for infectious disease transmission.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajic.2022.04.013DOI Listing

Publication Analysis

Top Keywords

mobile phones
20
baseline months
12
phones
8
months post-intervention
8
post-intervention geometric
8
acute care
8
mobile
5
efficacy bioburden
4
bioburden reduction
4
reduction intervention
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!