Biomechanical study of oblique lumbar interbody fusion (OLIF) augmented with different types of instrumentation: a finite element analysis.

J Orthop Surg Res

Department of Spine Surgery, Tianjin Hospital, Tianjin University, 406 Jiefang South Road, Hexi District, Tianjin, 300211, China.

Published: May 2022

Background: To explore the biomechanical differences in oblique lumbar interbody fusion (OLIF) augmented by different types of instrumentation.

Methods: A three-dimensional nonlinear finite element (FE) model of an intact L3-S1 lumbar spine was built and validated. The intact model was modified to develop five OLIF surgery models (Stand-alone OLIF; OLIF with lateral plate fixation [OLIF + LPF]; OLIF with unilateral pedicle screws fixation [OLIF + UPSF]; OLIF with bilateral pedicle screws fixation [OLIF + BPSF]; OLIF with translaminar facet joint fixation + unilateral pedicle screws fixation [OLIF + TFJF + UPSF]) in which the surgical segment was L4-L5. Under a follower load of 500 N, a 7.5-Nm moment was applied to all lumbar spine models to calculate the range of motion (ROM), equivalent stress peak of fixation instruments (ESPFI), equivalent stress peak of cage (ESPC), equivalent stress peak of cortical endplate (ESPCE), and equivalent stress average value of cancellous bone (ESAVCB).

Results: Compared with the intact model, the ROM of the L4-L5 segment in each OLIF surgery model decreased by > 80%. The ROM values of adjacent segments were not significantly different. The ESPFI, ESPC, and ESPCE values of the OLIF + BPSF model were smaller than those of the other OLIF surgery models. The ESAVCB value of the normal lumbar model was less than the ESAVCB values of all OLIF surgical models. In most postures, the ESPFI, ESPCE, and ESAVCB values of the OLIF + LPF model were the largest. The ESPC was higher in the Stand-alone OLIF model than in the other OLIF models. The stresses of several important components of the OLIF + UPSF and OLIF + TFJF + UPSF models were between those of the OLIF + LPF and OLIF + BPSF models.

Conclusions: Our biomechanical FE analysis indicated the greater ability of OLIF + BPSF to retain lumbar stability, resist cage subsidence, and maintain disc height. Therefore, in the augmentation of OLIF, bilateral pedicle screws fixation may be the best approach.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9107272PMC
http://dx.doi.org/10.1186/s13018-022-03143-zDOI Listing

Publication Analysis

Top Keywords

pedicle screws
16
screws fixation
16
equivalent stress
16
olif
14
olif surgery
12
stress peak
12
oblique lumbar
8
lumbar interbody
8
interbody fusion
8
fusion olif
8

Similar Publications

Study Design: Multicenter retrospective cohort study.

Objective: To evaluate the efficacy and safety of using cement-augmented pedicle screw (CAPS) fixation only for the cephalad and caudal vertebral bodies.

Summary Of Background Data: Pedicle screw fixation is less effective in patients with low-quality bone.

View Article and Find Full Text PDF

Purpose Of The Study: The annual number of spinal fusion procedures has been increasing and is well documented worldwide. The O-arm is slowly becoming the standard for transpedicular screw insertion. The accuracy and safety of this method have been confirmed by many studies.

View Article and Find Full Text PDF

Evaluation of Pedicle Screw Position on Computerized Tomography Using Three-Dimensional Reconstruction Software.

Medicina (Kaunas)

December 2024

Spine Center and Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea.

: Recent advances in intraoperative navigation systems have improved the accuracy of pedicle screw placement in spine surgery. However, many hospitals have limited access to these advanced technologies due to resource constraints. In such settings, postoperative computed tomography (CT) evaluation remains crucial for assessing screw placement and related potential complications.

View Article and Find Full Text PDF

Objective: We aimed to investigate the incidence of delayed-onset neurological deficits (DONDs), DOND-related reoperation rates following adult spinal deformity (ASD) surgery, and efficacy of transverse process hooks (TPHs) at the uppermost instrumented vertebra (UIV) compared to pedicle screws (PSs).

Methods: We included 90 consecutive patients who underwent instrumented fusion from the sacrum to the distal thoracic spine for ASD, with a minimum follow-up of 24 months. Clinical and radiological outcomes were compared between 33 patients in the TPH group and 57 patients in the PS group, using the Scoliosis Research Society-22 Outcomes questionnaire (SRS-22), Medical Outcomes Study Questionnaire Short-Form 36 (SF-36), and various spinal sagittal parameters.

View Article and Find Full Text PDF

Pedicle screws are commonly used for vertebral instrumentation, and a postoperative computed tomography (CT) scan is used to evaluate their position within the pedicle. Medial pedicle screw breaching occurs in 20%-40% of cases. This study investigated the correlation between radiographically evident medial breaching and the incidence of nerve injury, shedding light on the clinical implications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?