Background: Few studies have compared the efficacy of single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (VDD-ICD) and conventional single-chamber ICD from the aspect of atrial fibrillation (AF) detection or inappropriate ICD therapy reduction. In the SMART-CONTROL trial (NCT03932604), we primarily aim to investigate whether the atrial sensing capability of VDD-ICD is useful in AF detection and inappropriate therapy reduction by randomly activating or deactivating the atrial sensing function.

Methods And Design: This study was designed as a prospective, multicenter, open-label, randomized trial to enroll 640 patients with no history of clinical AF or rhythm control for AF within 1 year who were undergoing the implantation of VDD-ICD system. Patients are assigned randomly to atrial sensing "ON" or "OFF" group, with crossover allowed during follow-up. The coprimary outcomes are the incidence of AF detection and inappropriate ICD therapy over a 2-year follow-up period. The secondary outcomes include non-AF atrial tachyarrhythmia, ventricular tachyarrhythmia with or without ICD therapy, thromboembolic events, bleeding, heart failure hospitalization, mortality, a composite of adverse cardiovascular events, and long-term atrial sensing stability or variability.

Conclusion: We expect that this trial can evaluate the efficacy of a single-lead ICD system on various clinical outcomes including AF detection and inappropriate therapy reduction, and ultimately provide guidance to selection of ICD system.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ahj.2022.05.008DOI Listing

Publication Analysis

Top Keywords

atrial sensing
28
detection inappropriate
16
efficacy single-lead
12
inappropriate therapy
12
icd therapy
12
therapy reduction
12
atrial
10
single-lead implantable
8
implantable cardioverter-defibrillator
8
sensing dipole
8

Similar Publications

Background: Sequential application of radiofrequency with pulsed field (PF) ablation may increase lesion depth while preserving the advantages of PF. The study's aim was to determine lesion dimensions of sequential, colocalized radiofrequency and PF ablation.

Methods: A preclinical study using swine (n=4) performed lesions in the right/left ventricles.

View Article and Find Full Text PDF

A tailored substrate-based approach using focal pulsed field catheter ablation in patients with atrial fibrillation and advanced atrial substrate: Procedural data and 6-months success rates.

Heart Rhythm

January 2025

Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre, Maastricht, The Netherlands; Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark. Electronic address:

Background: Focal pulsed-field ablation (F-PFA) integrated in electroanatomical mapping (EAM) systems allows tailored lesion sets in patients with atrial fibrillation (AF).

Objective: To determine feasibility, safety and 6-months outcome of F-PFA for a tailored substrate-based catheter ablation (CA) approach in patients with AF and advanced atrial substrate.

Methods: Consecutive patients with AF and advanced atrial substrate treated by a F-PFA system (Cardiofocus) through contact-force sensing catheters integrated in EAM systems were prospectively enrolled.

View Article and Find Full Text PDF

Background: A novel contact force (CF) sensing catheter with a mesh-shaped irrigation tip (TactiFlexTM SE, Abbott), is expected to provide safe and effective radiofrequency ablation. Our previous study revealed that the TactiFlex catheter needs a higher power for pulmonary vein isolation (PVI) due to the long tip length. This study aimed to examine the feasibility and safety of a 50 W ablation with the TactiFlex for PVI of atrial fibrillation (AF).

View Article and Find Full Text PDF

Changes in Physical Activity and Cardiovascular Disease Risk in Cancer Survivors: A Nationwide Cohort Study.

JACC CardioOncol

December 2024

Department of Clinical Research Design and Evaluation, Samsung Advanced Institute for Health Science and Technology, Sungkyunkwan University, Seoul, Republic of Korea.

Background: Cancer survivors face an elevated risk of cardiovascular disease, with physical inactivity after cancer treatment potentially worsening this risk.

Objectives: The aim of this study was to investigate the association between physical activity before and after a cancer diagnosis and the risk for heart disease.

Methods: A nationwide cohort of 269,943 cancer survivors (mean age 56.

View Article and Find Full Text PDF

False Alarms in Wearable Cardioverter Defibrillators-A Relevant Issue or an Insignificant Observation.

J Clin Med

December 2024

Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité (DHZC), Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany.

The wearable cardioverter defibrillator (WCD) has emerged as a valuable tool used for temporary protection from sudden cardiac death. However, since the WCD uses surface electrodes to detect arrhythmias, it is susceptible to inappropriate detection. Although shock conversion rates for the WCD are reported to be high for detected events, its efficacy in clinical practice tends to be degraded by patient noncompliance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!