Objective: The aim of this study was to evaluate the effectiveness of cleansing protocols to remove sealer residues using different cleaning strategies and the effect of bond strength of two universal adhesives to dentin impregnated with epoxy resin-based sealer.

Materials And Methods: Fifty bovine dentin specimens were impregnated with epoxy resin-based sealer containing calcium hydroxide (Sealer Plus) and submitted to cleansing protocols (n = 10): negative control (NC), positive control (PC), 95% ethanol (ET), xylol (XI), and amyl acetate (AA). Specimens were evaluated by scanning electron microscope (SEM). Other 100 specimens were submitted to the same protocols (n = 20). Each protocol was divided into subgroups (n = 10) according to the universal adhesive system used: Scotchbond Universal (SU); Ambar Universal (AU). Bond strength was evaluated by micro-shear bond test (μSBT). Persistence of residues data were assessed with Kruskal-Wallis and Dunn's tests. μSBT data were analyzed with two-way ANOVA (α = 5%).

Results: ET presented higher persistence of residues compared to AA and XI (p < 0.05). AA and XI were similar from each other (p > 0.05). AU and SU presented similar μSBT values, regardless of the cleansing solution (p > 0.05). SU-NC presented the highest μSBT among all conditions (p < 0.05).

Conclusion: The bond strength of universal adhesives was not affected by different amounts of sealer residues after different cleaning protocols.

Clinical Significance: Non-polar substances such as amyl acetate and xylol are effective for removing residues from epoxy resin-based endodontic sealers.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jerd.12924DOI Listing

Publication Analysis

Top Keywords

cleansing protocols
12
protocols remove
8
sealer residues
8
universal adhesive
8
bond strength
8
impregnated epoxy
8
epoxy resin-based
8
persistence residues
8
universal
5
impact cleansing
4

Similar Publications

Transrectal oocyte retrieval for fertility preservation in virginal women.

Reprod Biomed Online

October 2024

Virginia Center for Reproductive Medicine, Reston, VA, USA; Department of Obstetrics and Gynecology, George Washington University, Washington, DC, USA. Electronic address:

Research Question: How safe and effective is transrectal oocyte retrieval (TROR) for fertility preservation in nulliparous virginal women?

Design: This was a retrospective single-centre study of 105 nulliparous women from five satellite centres of Fakih IVF, UAE, who underwent TROR for oocyte cryopreservation. Extensive bowel preparation and rectal cleansing was performed prior to oocyte retrieval. Patient characteristics, stimulation protocol, and procedure outcome and safety data were collected.

View Article and Find Full Text PDF

Description: Gastric cancer (GC) is a leading cause of preventable cancer and mortality in certain US populations. The most impactful way to reduce GC mortality is via primary prevention, namely Helicobacter pylori eradication, and secondary prevention, namely endoscopic screening and surveillance of precancerous conditions, such as gastric intestinal metaplasia (GIM). An emerging body of evidence supports the possible impact of these strategies on GC incidence and mortality in identifiable high-risk populations in the United States.

View Article and Find Full Text PDF

Background/aims: Small bowel capsule endoscopy (SBCE) has become the standard for initial evaluation in the diagnosis of small bowel lesions. Although optimal visualization of the mucosa is important, patients experience difficulty in consuming a large volume of bowel preparation agents. This study aimed to compare the efficacy and safety of 1-L polyethylene glycol (PEG) with ascorbic acid (AA) and 2-L PEG with AA.

View Article and Find Full Text PDF
Article Synopsis
  • Hemostatic agents are commonly used in dental procedures to control bleeding, but they can negatively impact the bonding of resin composites to dentin, making their removal before bonding important.
  • The study involved 90 premolar teeth divided into groups treated with either no hemostatic agent, ferric sulfate, or aluminum chloride, with cleanup methods including water, phosphoric acid, katana cleaner, and air abrasion.
  • Results showed that the type of hemostatic agent and cleansing method significantly affected bond strength, with phosphoric acid yielding the best results and ferric sulfate showing the lowest bond strength.
View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the effectiveness of a new skin cleaning protocol before the implantation of the artificial urinary sphincter (AUS) in reducing early device infections in men with severe stress urinary incontinence.
  • Researchers reviewed medical records from 2010 to 2023, comparing a standard cleansing protocol with a new enhanced protocol, looking for any difference in the rates of infections that led to explantation of the device.
  • Results indicated no significant difference in infection rates between the two cleaning methods, suggesting that the new protocol does not reduce the risk of early AUS complications and further research is needed to identify actual risk factors.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!