Guided implant surgery can enhance implant placement positioning, increasing predictability and decreasing postoperative complications., To date, the best protocol to be used for template realization is still unknown. Thus, the aim herein was to clinically compare the accuracy of two different protocols. A total of 48 implants were divided into Group A (24 implants), in which a stereolithographic template was realized using the digital imaging and communications in medicine (DICOM) data arrived from cone beam computer tomographies (CBCTs) (patients and prothesis alone), and Group B (24 implant), in which a standard intraoral stent with a standardized extraoral support was used for patients’ intraoral impressions and CBCT. The preimplant virtual planning and postsurgery CBCT images of both groups were superimposed, and differences were registered in terms of average deviations at the platform (a) and implant apex (b), mean depth change (c), and angular deviation (d). The results demonstrated that there were no statistically significant differences between groups (p = 0.76) for the parameters measured. However, statistically significant differences (p < 0.05) were found between maxillary and mandible implant surgery, as the latter showed greater accuracy. Additional studies are necessary to further reduce discrepancies between planning and surgical procedures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9101796PMC
http://dx.doi.org/10.3390/jcm11092336DOI Listing

Publication Analysis

Top Keywords

implant surgery
8
statistically differences
8
implant
5
accuracy dicom-dicom
4
dicom-dicom dicom-stl
4
dicom-stl protocols
4
protocols computer-guided
4
computer-guided surgery
4
surgery human
4
human clinical
4

Similar Publications

Where does the tether break in vertebral body tethering cases? Clinical insights from revision cases after tether breakage.

Spine Deform

January 2025

Department of Spine Surgery, Eifelklinik St Brigida, St. Brigida Eifelklinik, Kammerbruchst. 8, 52152, Simmerath, Germany.

Purpose: To evaluate the sites where the tether breaks in vertebral body tethering (VBT) cases.

Methods: Intraoperative evaluation of broken tethers in patients who had anterior revision.

Inclusion Criteria: anterior revision of VBT cases with explantation of the full implant and photo documentation.

View Article and Find Full Text PDF

Prognosis of Implant-Based Breast Reconstruction After Mastectomy Flap Necrosis: Predictors of Failure and Salvage.

Aesthetic Plast Surg

January 2025

Department of Plastic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea.

Background: In the realm of implant-based breast reconstruction, mastectomy flap necrosis (MFN) is a prevalent yet grave complication that poses a threat to the stability of the inserted prosthesis. Although numerous investigations have scrutinized the risk factors for MFN development, few have delved into the aftermath, specifically implant failure or salvage. This study seeks to appraise the prognosis of the implanted prosthesis following MFN occurrence, as well as identify predictors of such outcomes.

View Article and Find Full Text PDF

Short-term outcomes of mesh-suture repair in the treatment of ventral hernias: a single-center study.

Surg Endosc

January 2025

Division of Minimally Invasive and Bariatric Surgery, Penn State Health Milton S. Hershey Medical Center, 500 University Drive, Hershey, PA, 17033, USA.

Background: Defect closure with mesh suture is a novel technique for hernia repair. Originally described as the construction of lightweight macroporous polypropylene mesh strips as a suture material, it is now available as an FDA-approved product. Mesh suture better distributes tensile forces and reduces fascial tearing compared to traditional suture but requires less implanted material and tissue dissection compared to planar mesh.

View Article and Find Full Text PDF

In current alloplastic total temporomandibular joint replacements (TMJRs) typically the lateral pterygoid muscle (LPM) insertion is sacrificed, affecting joint function. This study assesses a novel additively manufactured TMJR (CADskills BV, Gent, Belgium) designed to enable LPM reinsertion through a scaffold feature on the implant. Thirteen TMJRs were implanted in Swifter crossbreed sheep, with follow-up CT scans after 288 days to evaluate LPM reintegration.

View Article and Find Full Text PDF

A young man in his 30s presented to us with multiple episodes of syncope and exertional dyspnoea for the last 2 weeks. He was diagnosed with squamous cell carcinoma of the lower one-third of the oesophagus in 2021 for which he was treated with neoadjuvant chemoradiotherapy, followed by McKeown oesophagectomy. At 2-year follow-up, he had developed a soft tissue swelling in the scalp, which was diagnosed as a tumour recurrence and radiotherapy was initiated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!