Background: Long-term clinical and radiographic outcome data after standard cemented long-stem reverse shoulder arthroplasty (RSA) remain underreported. The aim of this study is to report on medium- to long-term data of patients over 60 years of age. Methods: The same type of RSA (Aequalis Reverse II, Memphis, TN, USA) was implanted in 27 patients with a mean age of 73 years (range 61−84). Indications for RSA were cuff tear arthropathy (CTA) in 25 cases and osteoarthritis (OA) in two cases. Pre- and postoperative Constant Score was assessed and component loosening, polyethylene wear, scapular notching and revision rates were recorded at a mean clinical follow-up (FU) of 127.6 months (SD ± 33.7; range 83−185). Results: The mean-adjusted CS (aCS) improved from 30.0 (range 10−59) to 95.0 (range 33−141) points (p < 0.001). Glenoid loosening was found in two (9.1%) and stem loosening was found in three (13.6%) cases. Polyethylene wear was observed in four (18.2%) cases. Scapular notching appeared in 15 (68.2%) cases but was not associated with poor aCS (p = 0.423), high levels of pain (p = 0.798) or external rotation (p = 0.229). Revision surgery was necessary in three (11.1%) cases. Conclusions: RSA with a cemented standard long stem leads to improvement in forward elevation, abduction and pain after a mean FU of 10 years. However, external rotation does not improve with this prosthetic design. Moreover, scapular notching is observed in the majority of cases, and revision rates (11.1%) as well as humeral loosening rates (13.6%) remain a concern. Level of evidence: Level 4, retrospective cohort study.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9103013 | PMC |
http://dx.doi.org/10.3390/jcm11092274 | DOI Listing |
Curr Rev Musculoskelet Med
January 2025
Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA.
Purpose Of Review: With the growing popularity and broadening indications for Reverse Shoulder Arthroplasty (RSA), increasing modularity in design and adjustments to each component can enhance postoperative range of motion (ROM), thus expanding treatment capabilities. This review outlines the advancements developed to optimize ROM through modifications in glenoid and humeral components and the integration of computational tools for surgical planning.
Recent Findings: Enhancements in glenoid component design aim to mitigate complications like scapular notching and improve ROM, particularly in abduction and external rotation.
Tunis Med
December 2024
Department of trauma and orthopedics surgery. Mouwasat Hospital Dammam, 32263 Eastern Province Kingdom of Saudi Arabia.
Unlabelled: Introduction-Aim: Full-polyethylene glenosphere reverse shoulder arthroplasty (FP-RSA) known commonly as inverted-bearing concept utilizes a polyethylene glenosphere and metallic humeral liner. The aim was to assess mid-term outcomes of FP-RSA focusing on the incidence of scapular notching.
Methods: A retrospective analysis of 24 consecutive primary FP-RSA performed between 2017 and 2020 was conducted.
J Shoulder Elbow Surg
December 2024
Department of Trauma Surgery and Orthopedics - Medical University of Vienna, AKH Wien, Vienna, Austria. Electronic address:
Background: While outcomes following reverse shoulder arthroplasty (rTSA) have often been gauged through radiological assessments focusing on prosthesis position, there is increasing recognition of patient-reported outcomes, particularly satisfaction, as indicators of surgical success. The objective of this study was to correlate radiological findings with clinical outcomes, patient satisfaction, and health-related quality of life (HRQoL).
Materials And Methods: A retrospective evaluation was conducted on patients following rTSA at a minimum of two years postoperatively.
BMC Musculoskelet Disord
December 2024
Department for Shoulder and Elbow Surgery, Schulthess Clinic, Zürich, Switzerland.
Objective: The establishment of clinical registries is essential for the comprehensive evaluation of surgical outcomes. In 2006, the Schulthess Shoulder Arthroplasty Registry (SAR) was launched to systematically assess safety, implant longevity, functional outcomes, pain levels, quality of life, and patient satisfaction in individuals undergoing shoulder arthroplasty. This paper aims to outline the registry data and demonstrate how it is leveraged to improve clinical outcomes.
View Article and Find Full Text PDFCurr Rev Musculoskelet Med
December 2024
Department of Orthopaedic Surgery, University of California San Francisco, 500 Parnassus Ave MU-320W, San Francisco, CA, 94143, USA.
Purpose Of The Review: There have been tremendous modifications to the humeral component since Paul Grammont first introduced the reverse total shoulder arthroplasty in 1985. The purpose of this article is to review historical design features and their drawbacks and to summarize the clinical outcomes of modern designs.
Recent Findings: Decreasing the neck-shaft angle and increasing humeral lateralization have helped address problems of scapular notching and limited internal and external rotation that were common with traditional designs.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!