Gloves are one of the most important elements of personal protective equipment (PPE). To improve gloves properties, a lot of different methods of surface modifications are used. In this work, the application of geometric, chemical, and plasma surface modifications to improve the hydrophobicity of butyl (IIR) and silicone (MVQ) rubber are described. To characterise surface properties contact angle measurements, FT-IR spectroscopy and scanning electron microscopy were used. This study showed that when the chemical modification applied, the contact angle value increases compared to non-modified samples. In addition, plasma modification raised the contact angle value and smoothed the surface morphology. An increase in the polymer surfaces hydrophobicity was the observed effect of the three modifications of rubber.