Certified disposable respirators afford important protection from hazardous aerosols but lose performance as they are worn. This study examines the effect of wear time on filtration efficiency. Disposable respirators were worn by CSIRO staff over a period of 4 weeks in early 2020. Participants wore the respirator masks for given times up to eight hours whilst working in laboratory/office environments. At that time COVID-19 precautions required staff to wear surgical (or other) masks and increase use of hand sanitizer from dispenser stations. Results obtained from a test group of ten individuals without health preconditions show an increasing number of masks failing with wear time, while the remainder continue to perform nearly unaffected for up to 8 h. Some masks were found to retain filtration performance better than others, possibly due to the type of challenge they were subjected to by the wearer. However, the rate and extent of decay are expected to differ between environments since there are many contributing factors and properties of the aerosol challenge cannot be controlled in a live trial. Penetration and variability increased during wear; the longer the wear time, the more deleterious to particle removal, particularly after approximately 2 h of wear. This behavior is captured in a descriptive statistical model based on results from a trial with this test group. The effectiveness of the masks in preventing the penetration of KCl particles was determined before and after wearing, with the analysis focusing on the most penetrating particles in a size range of 0.3-0.5 µm diameter where respirator masks are most vulnerable. The basic elements of the study, including the approach to filter testing and sample sanitization, are broadly applicable. Conclusions also have applicability to typical commercially available single-use respirator masks manufactured from melt blown polypropylene as they are reliant on the same physical principles for particle capture and electrostatic enhancement was comparable for the particle size range used for detection.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9100139 | PMC |
http://dx.doi.org/10.3390/ijerph19095032 | DOI Listing |
J Clin Med
December 2024
Clinical Department 9, Faculty of Medicine, University of Medicine and Pharmacy "Carol Davila", 050474 Bucharest, Romania.
: The increasing prevalence of video gaming has raised concerns about its potential impact on musculoskeletal health, particularly temporomandibular disorders (TMDs). This study aims to compare TMD symptoms, mandibular function, and dental wear between gamers and non-gamers among university students. : An observational study included 108 students aged 20 to 23 years, divided into gamers (n = 48) and non-gamers (n = 60).
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Faculty of Mechanical Engineering and Mechatronics, West Pomeranian University of Technology in Szczecin, al. Piastów 19, 70-310 Szczecin, Poland.
This paper presents a comparative analysis of the energy efficiency of screw drive and linear drive CNC machine tools in turning operations. Two CNC lathes were investigated, one equipped with screw drives and the other with linear drives, during the turning of specially prepared parts. The research examines active and reactive energy consumption, offering insights into the energy efficiency of different drive technologies.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Faculty of Civil Engineering, Mechanics and Petrochemistry, Warsaw University of Technology, 09-400 Płock, Poland.
This article compares the rheological and tribological properties of three ionic liquids: Tributyl(methyl)phosphonium dimethyl phosphate 97%-MFCD, 1-Butyl-3-methylimidazolium hexafluorophosphate 97%-BMIMPF6, and 1-Butyl-3-methylimidazolium tetrafluoroborate 98%-BMIMBF4. Their density and kinematic viscosity at 20 °C and 40 °C were investigated, and tribological tests were carried out at the same temperatures with ball-on-disc contact. The test materials were made of 100Cr6 steel.
View Article and Find Full Text PDFOphthalmic Physiol Opt
January 2025
Elite School of Optometry, Medical Research Foundation, Chennai, India.
Purpose: To investigate changes in fluid reservoir turbidity parameters over time and its influence on visual performance in eyes with ocular surface disorders (OSD) wearing scleral contact lenses (SL).
Methods: Thirteen eyes with OSD were assessed for corrected distance visual acuity, contrast sensitivity (CS) and fluid reservoir turbidity using anterior segment optical coherence tomography at baseline, after 5 min and 0.5, 1, 2, 3 and 4 h of SL wear on day 1 and after 1 month.
Clin Optom (Auckl)
December 2024
Department of Mathematical Sciences, Worcester Polytechnic Institute, Worcester, MA, 01609, USA.
Purpose: Retrospective study to review scleral lens outcomes in the pediatric population over a 21-year period, at a single clinical center.
Results: A total of 209 pediatric eyes (108 males and 101 females), distributed between 97 right and 112 left eyes, of which 147 eyes had ocular surface disease and 62 eyes had irregular cornea/refractive conditions, were treated with scleral lenses over a 21-year period. The mean age at the time of treatment initiation was 10.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!