Purpose: To assess the safety and short-term occlusion rates in procedures using the p64 MW hydrophilic polymer-coated (HPC) flow diverter (FD) with prasugrel single antiplatelet therapy (SAPT) for the treatment of anterior circulation saccular aneurysms.
Methods: We retrospectively identified patients who underwent treatment of one or more intracranial anterior circulation saccular aneurysms between March 2020 and December 2021 with a p64 MW HPC FD and prasugrel SAPT with verified P2Y12 platelet receptor inhibition. Patients diagnosed with fusiform, dissecting, or recently ruptured aneurysms were excluded. Periprocedural and postprocedural complications, clinical outcomes, and angiographic follow-up results were evaluated.
Results: One hundred and two patients with 132 intracranial aneurysms met the inclusion criteria. Previous or concomitant treatments (e.g., coil occlusion) had been performed on 18 of these aneurysms. The technical success rate (i.e., implantation of the intended FD) was 100% with an average of 1.1 devices implanted per patient. Periprocedural and postprocedural complications occurred in 13.6% and 6.8% of these patients, respectively. No mortality or permanent clinical deterioration (i.e., modified Rankin scale score ≥ 3) were reported. Early follow-up digital subtraction angiography revealed aneurysmal occlusion rates of 72.6% and 83.8% at four and nine months, respectively.
Conclusions: The implantation of a p64 MW HPC FD with prasugrel SAPT is safe and results in rapid, reliable and effective aneurysmal occlusion.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9458553 | PMC |
http://dx.doi.org/10.1007/s00270-022-03153-8 | DOI Listing |
J Neurointerv Surg
August 2024
Neuroradiology, Klinikum Stuttgart Katharinenhospital, Stuttgart, Germany.
Background: This study reports a multicenter experience of using hydrophilic polymer-coated (HPC) flow diverters with prasugrel single antiplatelet therapy to treat ruptured aneurysms with subarachnoid hemorrhage (SAH).
Methods: Patients treated for intracranial aneurysms within 30 days after SAH with a p64/p48 MW HPC flow diverter were prospectively identified. Clinical presentation and outcomes, periprocedural and postprocedural complications, and degree of occlusion at follow-up were evaluated.
J Neurointerv Surg
June 2024
Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Background: Surface-modified flow diverters are increasingly used in clinical settings. However, their safety profiles and additional benefits over non-coated devices still need to be explored. In this meta-analysis, we aimed to investigate and compare the clinical outcomes of the uncoated Phenox and coated Phenox HPC flow diverters.
View Article and Find Full Text PDFJ Neurointerv Surg
October 2024
Interventional Neuroradiology, Universidade de São Paulo Faculdade de Medicina de Ribeirão Preto, Ribeirao Preto, Brazil
Background: A new generation of modified surface flow diverters (FDs) and monotherapy using new antiplatelets may reduce both ischemic and hemorrhagic complications during the treatment of intracranial aneurysms. Previous preliminary safety analysis of distal unruptured intracranial aneurysms treated with the FD p48 MW HPC (phenox-Wallaby, Bochum, Germany) under antiplatelet monotherapy with prasugrel showed promising results. However, the long term outcomes of distal intracranial aneurysms treated with FDs under antiplatelet monotherapy are not known.
View Article and Find Full Text PDFCardiovasc Intervent Radiol
September 2022
Neuroradiologische Klinik, Kopf- und Neurozentrum, Klinikum Stuttgart, Stuttgart, Germany.
Purpose: To assess the safety and short-term occlusion rates in procedures using the p64 MW hydrophilic polymer-coated (HPC) flow diverter (FD) with prasugrel single antiplatelet therapy (SAPT) for the treatment of anterior circulation saccular aneurysms.
Methods: We retrospectively identified patients who underwent treatment of one or more intracranial anterior circulation saccular aneurysms between March 2020 and December 2021 with a p64 MW HPC FD and prasugrel SAPT with verified P2Y12 platelet receptor inhibition. Patients diagnosed with fusiform, dissecting, or recently ruptured aneurysms were excluded.
Interv Neuroradiol
June 2022
Neuroradiological Clinic, Klinikum Stuttgart, Stuttgart, Germany.
Background: The p64MW HPC and p48MW HPC flow diverters have reduced thrombogenicity due to hydrophilic coating. The purpose of this study was to evaluate its safety and efficacy in Mongolian patients under single antiplatelet therapy (SAPT) with prasugrel.
Materials And Methods: We performed a retrospective review of patients enrolled into our prospectively maintained database to identify all patients treated with either the p48MW HPC or p64MW HPC under SAPT.