Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Hypothesis: The aim of this study was to evaluate the osteolysis rate, graft remodeling, and risk factors for osteolysis at the 1-year threshold after an arthroscopic Latarjet procedure with double-button fixation.
Method: In this multicenter, retrospective study, postoperative computed tomography scans obtained after an arthroscopic Latarjet procedure with double-button fixation to treat anterior shoulder instability were analyzed at 15 days and at 3, 6, and 12 months. Graft volume, dimensions, and morphologic remodeling were analyzed.
Results: Twenty-seven patients were included (mean age, 26 years). At 1 year, osteolysis occurred in 19 of 27 patients (70%). The volume initially decreased until 6 months' follow-up (-35%; range, -75% to +26%) and then increased until our last follow-up. At 1 year, the graft volume decreased by 17% (range, -61% to +56%) compared with the immediate postoperative volume. In multivariate analysis, the rate of osteolysis was inversely associated with an unhealed graft at 3 months (P = .02; β coefficient = -44.50 [95% confidence interval, -81 to -8]). The maximal height of the graft significantly grew 0.2 cm (range, -55 to +124 mm) (P = .015). In the sagittal plane, osteolysis occurred in the superior part in 100% of patients (27 of 27) whereas bone formation occurred in the inferior part. In the axial plane, osteolysis occurred in the anterior part whereas bone formation occurred in the posterior part. In the articular part, the observed remodeling was aimed to obtain a new anatomic and congruent glenoid.
Conclusions: At 1 year after an arthroscopic Latarjet procedure with double-button fixation, osteolysis occurred in 70% of patients. The rate of osteolysis was 17% of the initial volume. Osteolysis occurred mainly during the first 6 months, in the anterior and superior parts. Remodeling led to a circular anatomic glenoid. This osteolysis did not cause any recurrence of instability or require revision surgery.