Randomized prospective clinical trial of class II restorations using flowable bulk-fill resin composites: 4-year follow-up.

Clin Oral Investig

Department of Preventive and Restorative Dentistry, School of Dentistry Araçatuba, São Paulo State University (UNESP), José Bonifácio, Araçatuba, São Paulo, Vila Mendonça, 1193, Brazil.

Published: September 2022

Objectives: This randomized, prospective, and split-mouth study aimed to evaluate flowable bulk-fill resin composites in class II restorations, comparing it with a conventional layering technique after 4-year follow-up.

Materials And Methods: Fifty-three subjects received three class II restorations according to the restorative systems: conventional microhybrid composite resin (PA - Peak Universal + Amelogen Plus, Ultradent); flowable bulk-fill and nanoparticulate composite resins (ABF - Adper Single Bond 2 + Filtek Bulk Fill Flow + Filtek Z350XT, 3M/Espe); and flowable bulk-fill and microhybrid composite resins, (XST - XP Bond + SDR + TPH3, Dentsply). The clinical performance and interproximal contacts were evaluated. Statistical analyses were performed using the Kaplan-Meier, equality test of two proportions, Friedman, Wilcoxon, Kruskal-Wallis, Mann-Whitney, and Logistic regression analysis tests (alpha = 0.05).

Results: In total, 106 restorations were evaluated at 4 years. Both systems with bulk-fill composites presented higher marginal discoloration than PA. About surface texture, ABF restorative system showed superior bravo scores being statistically similar to XST. Better performance for wear and surface staining was found for XST restorative system. All restorative systems resulted in the decreased interproximal contacts, occurring early for XST.

Conclusions: The restorative systems that used flowable bulk-fill resin composites showed satisfactory clinical performance compared with conventional resin composite after 4 years. All restorative systems had decreased proximal contact after 4 years.

Clinical Relevance: Initial marginal discoloration was observed in more than 50% of class II restorations performed with restorative systems that used flowable bulk-fill resin composite. All restorative systems had decreased proximal contact strength over time.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00784-022-04526-6DOI Listing

Publication Analysis

Top Keywords

flowable bulk-fill
24
restorative systems
24
class restorations
16
bulk-fill resin
16
resin composites
12
systems decreased
12
randomized prospective
8
restorative
8
microhybrid composite
8
composite resins
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!