A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Different venous approaches for implantation of cardiac electronic devices. A network meta-analysis. | LitMetric

Objectives: Many of the complications arising from cardiac device implantation are associated to the venous access used for lead placement. Previous analyses reported that cephalic vein cutdown (CVC) is safer but less effective than subclavian vein puncture (SVP). However, comparisons between these techniques and axillary vein puncture (AVP) - guided either by ultrasound or fluoroscopy - are lacking. Thus, we aimed to compare safety and efficacy of these approaches.

Methods: We searched for articles assessing at least two different approaches regarding the incidence of pneumothorax and/or lead failure (LF). When available, bleeding and infectious complications as well as procedural success were analyzed. A frequentist random effects network meta-analysis model was adopted.

Results: Thirty-six studies were analyzed. Most articles assessed SVP versus CVC. Compared to SVP, both CVC and AVP were associated with reduced odds of pneumothorax (OR: 0.193, 95%CI: 0.136-0.275 and OR: 0.128, 95%CI: 0.050-0.329; respectively) and LF (OR: 0.63, 95%CI: 0.406-0.976 and OR: 0.425, 95%CI: 0.286-0.632; respectively). No significant differences between AVP and CVC were demonstrated. Limited data suggests no major impact of different approaches on infectious and bleeding complications. Initial CVC approach required significantly more often an alternate/additional venous access for lead placement, compared to both AVP and SVP. No differences between these two were identified.

Conclusion: Both AVP and CVC seem to decrease incident pneumothorax and LF, compared to SVP. Initial AVP approach seems to decrease the need of alternate venous access, compared to CVC. These results suggest that AVP should be further clinically tested.

Download full-text PDF

Source
http://dx.doi.org/10.1111/pace.14510DOI Listing

Publication Analysis

Top Keywords

venous access
12
network meta-analysis
8
access lead
8
lead placement
8
vein puncture
8
compared svp
8
cvc avp
8
avp cvc
8
cvc
7
avp
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!