A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

External Radiation Dose to Owners of Canines Treated with ( 117m Sn) Radiosynoviorthesis for Osteoarthritis. | LitMetric

A novel device in the veterinary market uses a colloid containing radioactive 117m Sn to treat osteoarthritis in the synovial joints of canines. The technique of injecting a radioisotope to restore synovia is referred to as radiosynoviorthesis. The outpatient canine procedure uses a maximum administration of 222 MBq of 117m Sn injected into one or more joints. Due to the 13.91 d half-life and 158.6 keV gamma output of 117m Sn, abiding by the annual public dose limit of 1 mSv is of primary regulatory concern. The therapy protocol starts with a pre-screening questionnaire to establish owner and animal behavior patterns. The questionnaire is used to determine the duration of written time and distance limitations post therapy. In this study, external radiation doses to owners were measured by providing optically stimulated luminescent dosimeters (OSLD) for up to 30 d post-treatment of the pet. Twelve owners were measured over various time frames at two licensed locations independent of each other. In one location, the average (OSLD) measured 0.029 mSv over a 14-d wear period. In the second location, the average (OSLD) measured 0.057 mSv over a 30-d wear period; both values were well below the recommended annual public dose. The overall average extrapolated external radiation dose was estimated at 0.092 mSv, while the maximum dose estimate was 0.25 mSv. The (OSLD) results and extrapolated owner doses provide reasonable assurance that the public dose limits will be met.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9232279PMC
http://dx.doi.org/10.1097/HP.0000000000001579DOI Listing

Publication Analysis

Top Keywords

external radiation
12
public dose
12
radiation dose
8
annual public
8
owners measured
8
location average
8
average osld
8
osld measured
8
wear period
8
dose
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!