A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrochemiluminescent detection of epilepsy biomarker miR-134 using a metal complex light switch. | LitMetric

Electrochemiluminescent detection of epilepsy biomarker miR-134 using a metal complex light switch.

Bioelectrochemistry

The National Epilepsy Programme, Beaumont Hospital, Dublin, Ireland, FutureNeuro, The SFI Research Centre for Chronic and Rare Neurological Disease, Dublin, Ireland, The Royal College of Surgeons in Ireland, Dublin, Ireland.

Published: August 2022

The detection of a key biomarker in epilepsy, miR-134, using an environmentally sensitive electrochemiluminescent luminophore, [Ru(DPPZ) PIC], is reported, DPPZ is dipyrido[3,2-a:2',3'-c]phenazine) and PIC is (2,2'-bipyridyl)-2(4-carboxy phenyl) imidazo [4,5][1,10] phenanthroline. A thiolated capture strand is first labelled with [Ru(DPPZ) PIC] and then adsorbed onto a gold electrode. No significant electrochemiluminescence, ECL, is observed for immobilised Ru-labelled capture strands which is consistent with the light-switch dye being exposed to the aqueous solution. In sharp contrast, binding of the target turns on ECL. The ECL intensity, I, depends on the number of adenine "spacer" bases between the end of the capture sequence and the dye. The ECL intensity for the optimised system increases linearly with increasing miR-134 concentration from 100 nM to approximately 20 μM. Single and double base mismatches produce I that are only approximately 30% and 8% respectively of that observed for the fully complementary target reflecting differences in their association constants. Significantly, the presence of BSA protein causes I to increase by less 5% in either the single or duplex circumstances. Finally, the ability of the sensor to quantify miR-134 in unprocessed plasma samples from healthy volunteers and people with epilepsy is reported.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bioelechem.2022.108150DOI Listing

Publication Analysis

Top Keywords

[rudppz pic]
8
ecl intensity
8
electrochemiluminescent detection
4
detection epilepsy
4
epilepsy biomarker
4
mir-134
4
biomarker mir-134
4
mir-134 metal
4
metal complex
4
complex light
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!