Passive sensors provide a new route for the characterization of concentration-dependent radiofrequency parameters with high reproducibility in real time. We propose a microfabricated resonator realized using integrated passive device technology for the sensitive detection and characterization of glucose. Experimental results verify the high performance of the proposed biosensor, because radiofrequency parameters such as resonance frequency (from 0.541 to 1.05 GHz) and reflection coefficient (from -34.04 to -24.11 dB) linearly vary in response to deionized water and subsequent iterative measurements of different glucose concentrations (from 50 to 250 mg dL). The biosensor has a very low limit of detection of 8.46 mg dL, a limit of quantitation of 25.63 mg dL, a minimum frequency sensitivity of 29 MHz, and a minimum magnitude sensitivity of 0.22 dB. Moreover, the coupling coefficient consistently decreases with the increasing glucose concentration. We also used the measured radiofrequency parameters to determine the unknown permittivity of glucose samples through mathematical modeling. A decreasing trend in the loss tangent and an increasing trend in the characteristic wave impedance were observed with the increase of glucose concentration. The reproducibility of the sensor was verified through iterative measurements on the same sensor surface and subsequent study of surface morphology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9086445PMC
http://dx.doi.org/10.1039/c8ra04243hDOI Listing

Publication Analysis

Top Keywords

radiofrequency parameters
12
detection characterization
8
characterization glucose
8
iterative measurements
8
glucose concentration
8
glucose
6
microfabricated passive
4
passive resonator
4
resonator biochip
4
biochip sensitive
4

Similar Publications

Fractional radiofrequency microneedling (FRM) is a popular, minimally invasive skin rejuvenation modality for treating acne scarring. In this study, we aimed to systematically evaluate the current literature on the efficacy and safety of FRM as a monotherapy to treat different types of facial acne scarring. We systematically reviewed all available literature on FRM techniques used for acne scarring by searching the PubMed and EBSCO databases up to July 2024.

View Article and Find Full Text PDF

Comparison of P-wave parameter changes after radiofrequency ablation and cryoballoon ablation for paroxysmal atrial fibrillation: An observational cohort study.

J Electrocardiol

January 2025

Department of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK; Department of Cardiovascular Sciences, Clinical Science Wing, University of Leicester, Glenfield Hospital, Leicester, UK; National Institute for Health Research Leicester Research Biomedical Centre, Leicester, UK.

Background: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) can be performed using one-shot cryoballoon ablation (cryo) or point-by-point radiofrequency ablation (RF). This study compares the changes in P-wave parameters between both ablation methods.

Methods: This single-centre retrospective study included contact force RF and second-generation cryo for PAF between 2018 and 2019.

View Article and Find Full Text PDF

We aimed to assess the uric acid-to-high-density lipoprotein cholesterol (HDL-C) ratio (UHR) and several other parameters with respect to their performance in detecting recurrence among patients with atrial fibrillation (AF) who underwent ablation. This retrospective cohort study analyzed data from patients who underwent radiofrequency or cryoablation for paroxysmal, persistent, or long persistent AF between September 2021 and September 2023. After ablation, patients were monitored for 24 h, with an ECG Holter used for symptomatic cases.

View Article and Find Full Text PDF

Purpose: This study explores the use of heart rate variability (HRV) analysis, a noninvasive technique for assessing the autonomic nervous system, by applying nonlinear dynamics and chaos theory to detect chaotic behavior in RR intervals and assess cardiovascular health.

Methods: Employing the "System Analysis of Heart Rate Dynamics" (SADR) program, this research combines chaos analysis with the short-time Fourier transform to assess nonlinear dynamic parameters in HRV. It includes constructing phase portraits in Takens space and calculating measures of chaos to identify deterministic chaos indicators.

View Article and Find Full Text PDF

Background: Radiofrequency microneedling (RFM) is a potential treatment for primary hyperhidrosis. However, its efficacy is unclear, and treatment parameters and outcomes vary across studies.

Objective: To understand the effect of RFM on treating primary hyperhidrosis, as measured by changes in the Hyperhidrosis Disease Severity Score (HDSS) before and after treatment, and to clearly define treatment settings most likely to optimize results.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!