Monte Carlo Dose Calculation - A QA Method for SRT and SBRT Plans in Treating Multiple and Small Metastatic Lesions.

J Med Phys

Department of Radiation Oncology, Fox Chase Cancer Center, Temple University, Philadelphia, Pennsylvania, USA.

Published: March 2022

To provide accurate and fast 3-D dose verification for hypofractionated stereotactic radiotherapy (SRT/SBRT) of small and multi targets calculated with a Varian Eclipse treatment planning system (TPS) delivered on a Varian accelerator. Ten brain and lung hypofractionated SRT/SBRT linac-based and CyberKnife plans were generated by the Eclipse system for delivery on the accelerator with the Millenium-120 leaf multileaf collimator (MLC) and Multiplan for the CyberKnife machine. These clinical SRT/SBRT plans required accurate quality assurance measurements to obtain absolute point dose and 3-D dose distributions due to the low number of fractions and high fraction doses. For small-field and multi-target plans, the EGS4/MCSIM code was used to calculate the dose distribution. A 0.125 cc ion chamber, a 0.016 cc pin-point chamber and Kodak EDR2 film were used for the measurements and the results were compared with Monte Carlo (MC) calculations. The dosimetry for small-field and multi-target treatment plans is challenging due to the comparable range of secondary electrons and the field sizes defined by SRT/SBRT MLC segments. Our MC simulations can accurately reproduce the linac dose distributions (within 1%/1 mm) three dimensionally. For the clinical SRT/SBRT plans investigated in this work, the MC doses agreed within 3% with ion chamber measurements and within 2%/2 mm with film measurements. The doses calculated by the Eclipse AAA algorithm and Multiplan differed by no more than 5% from MC calculations for small (4-40 cc) Planning Target Volumes (PTVs). MC dose calculation provides accurate and fast 3-D dose verification for hypofractionated SRT for small and multi-target treatment plans generated by a Varian Eclipse TPS on a Varian accelerator and Multiplan treatment planning on the CyberKnife System.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9084579PMC
http://dx.doi.org/10.4103/jmp.jmp_123_21DOI Listing

Publication Analysis

Top Keywords

3-d dose
12
monte carlo
8
dose
8
dose calculation
8
accurate fast
8
fast 3-d
8
dose verification
8
verification hypofractionated
8
varian eclipse
8
treatment planning
8

Similar Publications

Objectives: This study aimed to evaluate the safety profile of the recombinant zoster vaccine (RZV) after its marketing in China.

Methods: We present a descriptive analysis and safety signal assessment of adverse events following immunization (AEFI) associated with RZV between September 2020 and December 2023. The descriptive data collected includes demographic characteristics and the classification of characteristics of AEFI cases, while vaccine safety signal assessment was evaluated using the reporting odds ratio (ROR).

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to create a predictive model for late rectal bleeding in prostate cancer patients undergoing different types of radiotherapy.
  • Candidate predictors were identified from prior research and five logistic regression models were tested based on various dose parameters.
  • Results indicated that certain dosimetric predictors and history of abdominal surgery were significant for predicting the outcome, with some models showing satisfactory internal validation, but external validation is necessary for confirmation.
View Article and Find Full Text PDF

In the field of toxicology, male reproductive hazards attributed to metal exposure is a fast-developing issue. Mercury has been identified as an environmental pollutant that causes potential adverse impacts on organisms. This study aimed to assess the reprotoxic consequences of mercuric chloride (HgCl).

View Article and Find Full Text PDF

A series of 2-(4-bromobenzyl) tethered 4-amino aryl/alkyl-5,6,7,8-tetrahydrobenzo[4,5]thieno[2,3-]pyrimidines (7a-7u) were designed, synthesized, characterized and screened against a panel of cancer cell lines. Compound 7a, in particular, emerged as a potent antiproliferative agent against FaDu cells (HTB-43) with an IC value of 1.73 μM.

View Article and Find Full Text PDF

The calculation of the relative bioavailability (RBV) of rumen-protected AA supplements using the plasma free AA dose-response technique currently relies on blood samples obtained 2, 4, 6, and 8 h after the 0500 h feeding during the last 3 d of each period in Latin square experiments with cows fed every 8 h (0500, 1300, and 2100 h). The objective of this study was to determine if this current blood sampling protocol captures the changes that may occur in plasma Met concentrations within a 24-h day to adequately determine the RBV of Met from Smartamine M (SM). Five multiparous lactating Holstein cows were used in a 5 × 5 Latin square design with 7-d periods.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!