Development of Low-Cost and Portable Pulse Oximeter Device with Improved Accuracy and Accessibility.

Med Devices (Auckl)

School of Biomedical Engineering, Jimma Institute of Technology, Jimma University, Jimma, Oromia, Ethiopia.

Published: May 2022

Purpose: In a clinical setting, blood oxygen saturation is one of the most important vital sign indicators. A pulse oximeter is a device that measures the blood oxygen saturation and pulse rate of patients with various disorders. However, due to ethical concerns, commercially available pulse oximeters are limited in terms of calibration on critically sick patients, resulting in a significant error rate for measurement in the critical oxygen saturation range. The device's accessibility in developing countries' healthcare settings is also limited due to portability, cost implications, and a lack of recognized need. The purpose of this study was to develop a reliable, low-cost, and portable pulse oximeter device with improved accuracy in the critical oxygen saturation range.

Methods: The proposed device measures oxygen saturation and heart rate using the reflectance approach. The rechargeable battery and power supply from the smartphone were taken into account, and the calibration in critical oxygen saturation values was performed using Prosim 8 vital sign simulator, and by comparing with a standard pulse oximeter device over fifteen iterations.

Results: The device's prototype was successfully developed and tested. Oxygen saturation and heart rate readings were both accurate to 97.74% and 97.37%, respectively, compared with the simulator, and an accuracy of 98.54% for the measurement of blood oxygen saturation was obtained compared with the standard device.

Conclusion: The accuracy of oxygen measurement attained in this study is significant for measuring oxygen saturation for patients in critical care, anesthesia, pre-operative and post-operative surgery, and COVID-19 patients. The advancements made in this research have the potential to increase the accessibility of pulse oximeter in resource limited areas.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9084508PMC
http://dx.doi.org/10.2147/MDER.S366053DOI Listing

Publication Analysis

Top Keywords

oxygen saturation
36
pulse oximeter
20
oximeter device
16
blood oxygen
12
critical oxygen
12
oxygen
10
saturation
9
low-cost portable
8
portable pulse
8
device improved
8

Similar Publications

Objective: The primary goal was to investigate whether the presence of preoperative lacunar infarcts (LACI) was associated with postoperative delirium (POD) in elderly patients undergoing elective major abdominal surgery.

Design: A prospective cohort study.

Setting And Participants: Patients aged ≥ 65 years from a tertiary level A hospital in China.

View Article and Find Full Text PDF

Background: Anthrax is a life-threatening zoonotic disease caused by Gram-positive, spore-forming bacterium . It manifests as a cutaneous, gastrointestinal, and respiratory disease. The cutaneous form ranges from a self-limiting lesion to severe edematous lesions with toxemic shock.

View Article and Find Full Text PDF

A 69-year-old man with chest pain was diagnosed with acute type B aortic dissection with the entry tear located at distal arch and a distal aortic arch aneurysm. Therefore, we performed debranching thoracic endovascular aortic repair 2 weeks after type B aortic dissection onset. First, the graft was anastomosed to bilateral axillary arteries.

View Article and Find Full Text PDF

The risk of cardiovascular disease differs among various ethnic groups, highlighting disparities in cardiovascular health among different populations. While multiple studies from other countries have looked at changes in physiological parameters during autonomic function tests like isometric handgrip and cold pressor tests, no correlational research has been done in Saudi Arabia. This lacuna underscores the importance of examining the relationship between cardiorespiratory parameters in young Saudi Arabian individuals during these tests.

View Article and Find Full Text PDF

Background: This study investigates the correlation between the difference in hematocrit (HCT) and serum albumin (ALB) levels (HCT-ALB), muscle tissue oxygen saturation (SmtO2), capillary refill time (CRT), and blood lactate (Lac) with the severity of renal function damage and prognosis in patients with septic shock.

Methods: Conducted from February 2022 to February 2024, this study included 116 septic shock patients treated at the First Affiliated Hospital of Anhui Medical University. Patients were divided into groups based on whether they developed acute kidney injury: 40 patients were included in the acute kidney injury group, and the remaining 76 were placed in the non-kidney injury group.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!