Rehearsal simulation to determine the size of device for left atrial appendage occlusion using patient-specific 3D-printed phantoms.

Sci Rep

Department of Biomedical Engineering, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, South Korea.

Published: May 2022

Left atrial appendage (LAA) occlusion (LAAO) is used to close the finger-like extension from the left atrium with occlusion devices to block the source of thrombosis. However, selection of the devices size is not easy due to various anatomical changes. The purpose of this study is patient-specific, computed tomography angiography (CTA)-based, three-dimensionally (3D) printed LAAO phantoms were applied pre-procedure to determine the size. Ten patients were enrolled prospectively in March 2019 and December 2020. The cardiac structure appearing in CTA was first segmented, and the left atrium and related structures in the LAAO procedure were modeled. The phantoms were fabricated using two methods of fused deposition modeling (FDM) and stereolithography (SLA) 3D printers with thermoplastic polyurethane (TPU) and flexible resin materials and evaluated by comparing their physical and material properties. The 3D-printed phantoms were directly used to confirm the shape of LAA, and to predict the device size for LAAO. In summary, the shore A hardness of TPU of FDM was about 80-85 shore A, and that of flexible resin of SLA was about 50-70 shore A. The measurement error between the STL model and 3D printing phantoms were 0.45 ± 0.37 mm (Bland-Altman, limits of agreement from - 1.8 to 1.6 mm). At the rehearsal, the estimations of device sizes were the exact same with those in the actual procedures of all 10 patients. In conclusion, simulation with a 3D-printed left atrium phantom could be used to predict the LAAO insertion device size accurately before the procedure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9095622PMC
http://dx.doi.org/10.1038/s41598-022-11967-2DOI Listing

Publication Analysis

Top Keywords

left atrium
12
determine size
8
left atrial
8
atrial appendage
8
3d-printed phantoms
8
flexible resin
8
device size
8
size
5
left
5
phantoms
5

Similar Publications

Atrial cardiomyopathy (AC) has been defined by the European Heart Rhythm Association as "Any complex of structural, architectural, contractile, or electrophysiologic changes in the atria with the potential to produce clinically relevant manifestations".1 The left atrium (LA) plays a key role in maintaining normal cardiac function; in fact atrial dysfunction has emerged as an essential determinant of outcomes in different clinical scenarios, such as valvular diseases, heart failure (HF), coronary artery disease (CAD) and atrial fibrillation (AF). A comprehensive evaluation, both anatomical and functional, is routinely performed in cardiac imaging laboratories.

View Article and Find Full Text PDF

Background: The differential diagnosis of cardiac myxomas (CM), the most common benign primary cardiac tumors, is broad and a thorough diagnostic workup is required to establish accurate diagnosis prior to surgical resection. Transthoracic echocardiography (TTE) is usually the first imaging modality used for diagnosis of suspected CM. In a single tertiary centre study, we sought to determine the accuracy, sensitivity, and specificity of TTE in the diagnosis of CM and to determine echocardiographic characteristics indicative of CM.

View Article and Find Full Text PDF

Background: Cardiac involvement represents the main cause of death in patients with Fabry disease (FD). Echocardiography and cardiovascular magnetic resonance (CMR) have an established diagnostic role, but their prognostic value remains unresolved. This systematic review and meta-analysis sought to assess the prognostic implications of imaging parameters in FD.

View Article and Find Full Text PDF

Significance: Radiofrequency ablation to treat atrial fibrillation (AF) involves isolating the pulmonary vein from the left atria to prevent AF from occurring. However, creating ablation lesions within the pulmonary veins can cause adverse complications.

Aim: We propose automated classification algorithms to classify optical coherence tomography (OCT) volumes of human venoatrial junctions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!