Purpose: The purpose of this study was to assess the diagnostic performance of measurements from a new noninvasive, automated ocular surface analyzer (IDRA) in the diagnosis of dry eye disease (DED).
Methods: We prospectively identified patients with and without DED using best practice methods. Subsequently, all participants underwent IDRA analysis, consisting of 5 components: noninvasive tear film break-up time, tear meniscus height, lipid layer interferometry, eye blink quality, and infrared meibography. The manufacturer provides cutoff values for a pathologic result for each of these components. Using a stepwise augmentation multivariate logistic regression model, we identified the components with the strongest association for the presence of DED. For the 3 components with the strongest association (interferometry, tear meniscus, and infrared meibography), we calculated the probability of DED.
Results: We enrolled 40 patients (80 eyes) with DED (mean age 60.5 years; women 78.3%) and 35 healthy subjects (70 eyes, mean age 31.1 years; women 21.7%). The IDRA had an area under the curve of 0.868 (95% confidence interval: 0.809-0.927) to detect DED. A normal (≥80) interferometry combined with a normal (>0.22) tear meniscus and a normal (≤40) infrared meibography was associated with an estimated probability of 18% for the presence of DED, whereas the estimated probability of DED was as high as 96% when all 3 findings were pathologic.
Conclusions: The results of IDRA showed a positive concordance with routine clinical diagnostic tests. The new analyzer is an easy-to-access diagnostic tool to rule out the presence of DED in the extramural setting and to guide a timely DED treatment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/ICO.0000000000003052 | DOI Listing |
Purpose: The objective was to use cyclic tensile loading to compare the gap formation at suture site of three different suture materials to repair bovine radial meniscal tears: (1) polyglactin sutures, (2) tough adhesive puncture sealing (TAPS) sutures and (3) ultra-high molecular weight polyethylene (UHMWPE) sutures.
Methods: Twelve ex vivo bovine knees were dissected to retrieve the menisci. Complete radial tears were performed on 24 menisci, which were then separated into three groups and repaired using either pristine 2-0 polyglactin sutures, TAPS sutures (2-0 polyglactin sutures coated with adhesive chitosan/alginate hydrogels) or 2-0 UHMWPE sutures with a single stitch.
Indian J Orthop
January 2025
Ivy Hospital, Mohali, Punjab India.
Objective: This study aims to enhance our understanding of the morphological pattern, causes and pathogenesis of meniscal root injuries in the Indian population.
Materials And Methods: Sixty-four patients with meniscus root tears were included in the study. The patients were categorized into two groups based on the location of the meniscus tear: Group 1 ( = 41) comprised patients with lateral meniscus root injury (LMRI), and Group 2 ( = 23) included patients with medial meniscus root injury (MMRI).
Optom Vis Sci
December 2024
Department of Biostatistics, LV Prasad Eye Institute, Hyderabad, Telangana, India.
Significance: Artificial tears remain the cornerstone for managing dry eye disease. The current study's real-world efficacy test of carboxymethylcellulose (CMC), polyethylene glycol (PEG) 400, or sodium hyaluronate (SH)-based lubricants highlights their similar effects on noninvasive tear film parameters over the short term. However, patients reported better relief with SH-based lubricants.
View Article and Find Full Text PDFCurr Rev Musculoskelet Med
December 2024
Department of Orthopaedics, The Ohio State University Wexner Medical Center, 2835 Fred Taylor Dr. Suite 2200, Columbus, OH, 43202, USA.
Purpose Of Review: The management of horizontal cleavage meniscus tears (HCT) has evolved in recent years. Historically, HCTs have been treated with partial meniscectomy, but multiple studies have shown the long-term risks of development of arthritic changes in the knee following meniscectomy. These findings have renewed interest in meniscal preservation whenever possible, even in older patients not previously considered for meniscus repair.
View Article and Find Full Text PDFJt Dis Relat Surg
January 2025
İstanbul Medeniyet Üniversitesi Göztepe Prof. Dr. Süleyman Yalçın Şehir Hastanesi, Ortopedi ve Travmatoloji Kliniği, 34722 Kadıköy, İstanbul, Türkiye.
This case report highlights a rare complication of arthroscopic meniscal tear which is an arteriovenous fistula and pseudoaneurysm of the superior medial geniculate artery. A 14-year-old male patient presented with persistent hemarthrosis following arthroscopic repair of a bucket handle medial meniscal tear. The patient was investigated due to suspicion of vascular damage.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!