Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Intraoperative hypotension (IH) is an independent predictor of mortality. Some experts have suggested that ultrasound measurement of the inferior vena cava (IVC) in spontaneous ventilation can predict IH.
Objective: To evaluate the capacity of ultrasound measures of IVC in spontaneous ventilation to predict episodes of IH after anaesthesia induction.
Patients And Methods: We studied 55 high-risk cardiac patients undergoing vascular surgery. The maximum (dIVCmax) and minimum (dIVCmin) diameter of the IVC were measured and the collapsibility index CI = (dIVCmax-dIVCmin)/dIVCmax was calculated prior to anaesthesia induction. Three definitions of IH were used: systolic blood pressure (SBP) less than 100 mmHg, mean arterial pressure (MAP) less than 60 mmHg, and a decrease in MAP greater than or equal to 30% compared to baseline.
Results: There were no significant differences in dIVCmax or in CI between patients presenting IH after anaesthesia induction and those who did not. ROC curves for dIVCmax showed an area under the curve of 0.55 (0.39-0.70), 0.69 (0.48-0.90), and 0.57 (0.42-0.73) and ROC curves for the CI were 0.62 (0.47-0.78), 0.60 (0.41-0.78) and 0.62 (0.47-0.78) for the 3 definitions of IH (<100 mmHg, MAP < 60 mmHg, and MAP ≥30% baseline), respectively.
Conclusions: Ultrasound measurements of IVC in spontaneous ventilation are not good predictors of IH after anaesthesia induction in these patients. The optimal cut-off points show low specificity and moderate sensitivity for predicting IH.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.redare.2021.03.013 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!