The study presents the development and validation of a method for the determination of seven priority polycyclic aromatic hydrocarbons (PAHs, including fluoranthene and benzo[a]pyrene, for which the EU has set environmental quality standards, EQS, for biota) in gammarid samples combining focused ultrasound solid-liquid extraction and dispersive solid-phase extraction clean-up in one step followed by gas chromatography-triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS). The method is designed to analyse small about 100 mg dry weight (dw) samples obtained after lyophilisation of 500 mg wet weight (ww) samples. The sample preparation procedure is simple, environment friendly (method was classified as "an excellent green analysis" according to the analytical Eco-Scale assessment), non-laborious and low-cost and, apart from the sample extract concentration step, is quick. Thorough disintegration of the gammarids is achieved by a combination of sonication and the addition of granular anhydrous NaSO to the gammarid suspension, thus avoiding the need to grind the sample prior to analysis. The QqQ-MS/MS detector, thanks to its excellent selectivity and sensitivity, allows to meet the EQS requirements for PAHs in biota with a good margin (limits of quantification in the range of 0.12 and 0.56 ng g ww). The method has been successfully validated (in terms of linearity, method limits, precision, trueness, robustness, measurement uncertainty and comparative analysis of real samples), and has been shown to be suitable for monitoring and evaluating the PAHs contamination in surface water biota.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2022.463098DOI Listing

Publication Analysis

Top Keywords

focused ultrasound
8
ultrasound solid-liquid
8
solid-liquid extraction
8
extraction dispersive
8
dispersive solid-phase
8
solid-phase extraction
8
extraction clean-up
8
mass spectrometry
8
polycyclic aromatic
8
aromatic hydrocarbons
8

Similar Publications

The blood-brain barrier (BBB) remains an obstacle for delivery of chemotherapeutic agents to gliomas. High grade and recurrent gliomas continue to portend a poor prognosis. Multiple methods of bypassing or manipulating the BBB have been explored, including hyperosmolar therapy, convection-enhanced delivery (CED), laser-guided interstitial thermal therapy (LITT), and Magnetic Resonance Guided Focused Ultrasound (MRgFUS) to enhance delivery of chemotherapeutic agents to glial neoplasms.

View Article and Find Full Text PDF

Application of ultrasound elastography and splenic size in predicting post-hepatectomy liver failure: Unveiling new clinical perspectives.

World J Gastroenterol

January 2025

Department of Gastroenterology, Nanchong Central Hospital, The Second Clinical Medical College, North Sichuan Medical College, Nanchong 637000, Sichuan Province, China.

In this article, we discuss the study by Cheng , published in the , focusing on predictive methods for post-hepatectomy liver failure (PHLF). PHLF is a common and serious complication, and accurate prediction is critical for clinical management. The study examines the potential of ultrasound elastography and splenic size in predicting PHLF.

View Article and Find Full Text PDF

Solid organ tumors present a significant healthcare challenge, both economically and logistically, due to their high incidence and treatment complexity. In 2023, out of the 1.9 million new cancer cases in the United States, over 73% were solid organ tumors.

View Article and Find Full Text PDF

Introduction: We aim to critically assess Microultrasound (mUS) clinical performance in an outpatient setting, focusing on its ability to reduce unnecessary diagnostic procedures, potentially reshape prostate cancer (PCa) diagnostic protocols, and increase the ability to rule out clinically significant (Gleason Score ≥ 3 + 4) PCa (csPCa).

Materials And Methods: Between November 2018 and April 2022, we conducted a prospective study involving men who underwent mUS examination due to clinical symptoms, PSA elevation, or opportunistic early detection of PCa. Experienced urologists performed mUS assessments in an outpatient setting using the prostate risk identification using micro-ultrasound (PRI-MUS) protocol to identify lesions suspicious of csPCa (PRI-MUS score ≥ 3).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!