Monitoring of the coagulation function has applications in many clinical settings. Routine coagulation assays in the clinic are sample-consuming and slow in turnaround. Microfluidics provides the opportunity to develop coagulation assays that are applicable in point-of-care settings, but reported works required bulky sample pumping units or costly data acquisition instruments. In this work, we developed a microfluidic coagulation assay with a simple setup and easy operation. The device continuously generated droplets of blood sample and buffer mixture and reported the temporal development of blood viscosity during coagulation based on the color appearance of the resultant droplets. We characterized the relationship between blood viscosity and color appearance of the droplets and performed experiments to validate the assay results. In addition, we developed a prototype analyzer equipped with simple fluid pumping and economical imaging module and obtained similar assay measurements. This assay showed great potential to be developed into a point-of-care coagulation test with practical impact.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acssensors.1c02360 | DOI Listing |
Vet Med (Praha)
November 2024
Department of Veterinary Surgery, College of Veterinary Medicine, Jeonbuk National University, Republic of Korea.
This study aimed to measure the whole blood viscosity (WBV) in racehorses using a new viscometer and establish reference values, as well as to investigate the correlation between the WBV and the haematological parameters and serum chemistry. WBV measurements were conducted on 51 Thoroughbred horses using a novel U-shaped scanning capillary-tube viscometer. The reference values for the WBV were determined at various shear rates ranging from 1 s to 1 000 s.
View Article and Find Full Text PDFComplement Ther Clin Pract
January 2025
Department of Endocrinology, The First Affiliated Hospital of Henan University of Chinese Medicine, Zhengzhou, China. Electronic address:
Background And Purpose: Numerous studies have demonstrated the effectiveness of Chinese medicine injections (CMIs) in treating diabetic lower extremity arterial disease (Dia-LEAD). However, with the variety of CMIs available, it has become challenging to determine the optimal choice for Dia-LEAD patients. This study aims to compare and rank the efficacy of CMIs for Dia-LEAD to provide references and evidence for clinicians in optimising drug selection.
View Article and Find Full Text PDFCardiovasc Diagn Ther
December 2024
Cardiovascular Center, St. Luke's International Hospital, Tokyo, Japan.
Right ventricular (RV) dysfunction after biventricular repair is critical in most adults with congenital heart disease (ACHD). Conventional 2D magnetic resonance imaging (MRI) measurement is considered as a 'gold standard' for RV evaluation; however, addition information on ACHD after biventricular repair is sometimes required. The reasons why adjunctive information is required is as follows: (I) to evaluate the severity of cardiac burden in symptomatic patients with normal RV size and ejection fraction (EF), (II) to determine the optimal timing of invasive treatments in asymptomatic ones, and (III) to detect proactively a potential cardiac burden leading to ventricular deterioration, from a fluid dynamics perspective.
View Article and Find Full Text PDFActa Neurochir (Wien)
January 2025
Division of Neurosurgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street , Boston, MA, 02215, USA.
Background: Variability in long-term endovascular treatment outcomes for intracranial aneurysms has prompted questions regarding the effects of these treatments on aneurysm hemodynamics. Endovascular techniques disrupt aneurysmal blood flow and shear, but their influence on intra-aneurysmal pressure remains unclear. A better understanding of aneurysm pressure effects may aid in predicting outcomes and guiding treatment decisions.
View Article and Find Full Text PDFElectromagn Biol Med
January 2025
Department of Applied Mathematics, University of Calcutta, Kolkata, India.
The current investigation explores tri-hybrid mediated blood flow through a ciliary annular model, designed to emulate an endoscopic environment. The human circulatory system, driven by the metachronal ciliary waves, is examined in this study to understand how ternary nanoparticles influence wave-like flow dynamics in the presence of interfacial nanolayers. We also analyze the effect of an induced magnetic field on Ag-Cu-/blood flow within the annulus, focusing on thermal radiation, heat sources, buoyancy forces and ciliary motion.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!