Introduction: To our knowledge, no papers have reported the results of robotic-assisted surgery for sequential bilateral Total Knee Arthroplasty (TKA). Indeed, sequential bilateral TKA present several benefits, as one single anesthesia, surgical episode, hospitalization, and rehabilitation. The purpose of our study was to evaluate peri-operative outcomes and compare the complication rates, clinical outcomes, and implant positioning of sequential bilateral TKA performed with a robotic-assisted system versus a conventional technique.
Materials And Methods: All patients who underwent a sequential bilateral robotic-assisted primary TKA (raTKA) in our institution between November 2019 and February 2021 were included. Twenty patients met the inclusion criteria and were matched with 20 sequential bilateral TKA performed with a conventional technique. The two groups were comparable for the demographic data and the preoperative parameters, including preoperative anticoagulation and ASA score. The minimum follow-up was 6 months.
Results: The operative time was significantly longer in the robotic group (< 0.0001), with a mean additional time of 29 min. There was no significant difference between both groups for postoperative blood loss, rate of blood transfusion, or postoperative pain. The average length of stay was 5 days. There was one early complication in the robotic group due to the tibial trackers. The functional outcomes were similar between both groups, except for the functional KSS score, which was better at 6 months in the robotic group (p < 0.0001). The restoration of the knee alignment and the distal femoral anatomy were significantly better in the robotic group than in the conventional group.
Conclusions: Despite a longer operative time, the peri-operative parameters of sequential bilateral TKA were similar between robotic and conventional techniques. Further, sequential bilateral raTKA was at least as safe as a conventional technique, without additional risk of medical complications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00402-022-04455-9 | DOI Listing |
J Prosthet Dent
January 2025
Associate Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.
Statement Of Problem: Intraoral scans can be articulated in maximum intercuspal position (MIP) by using an artificial intelligence (AI) based program; however, the impact of edentulous areas on the accuracy of the MIP located using this AI-based program is unknown.
Purpose: The purpose of this in vitro study was to assess the impact of edentulous areas (0, 1, 2, 3, and 4 posterior mandibular teeth) on the accuracy of the MIP located using 3 intraoral scanners (IOSs) and an AI-based program.
Material And Methods: Stone casts articulated in MIP in an articulator were digitized (T710).
Neurophotonics
January 2025
Weill Cornell Medicine, Department of Neurological Surgery, New York, United States.
Significance: Despite the availability of various anti-seizure medications, nearly 1/3 of epilepsy patients experience drug-resistant seizures. These patients are left with invasive surgical options that do not guarantee seizure remission. The development of novel treatment options depends on elucidating the complex biology of seizures and brain networks.
View Article and Find Full Text PDFChemistry
January 2025
East China Normal University, Shanghai Key Laboratory of Green Chemistry and Chemical Process, 3663 North Zhongshan Road, 200062, Shanghai, CHINA.
Polysulfides play an essential role across a variety of fields, including life sciences, pharmaceuticals, food science, and materials science. However, the controlled sequential installation of groups at both ends of an S-S motif poses enormous challenges due to the reversible nature of the covalent S-S bond. The application of unique disulfide reagents presents one of the most straightforward approaches for constructing diverse polysulfides.
View Article and Find Full Text PDFJ Orthop
July 2025
MBBS, FRACS, FAOthA, Consultant Orthopaedic Surgeon, Melbourne Orthopaedic Group, Melbourne, Victoria, Australia.
Background: A contemporary trend favours a restricted kinematic alignment (rKA) strategy, incorporating safe boundaries to restore a variable percentage of a patient's natural alignment.This study aims to compare preoperative and postoperative coronal plane knee alignment (CPAK) in patients undergoing bilateral TKA with SAIPH implants (MatOrtho, UK). The concept was to control the implant (same prosthesis both sides), patient (bilateral model) and assess what effect any surgical alteration in alignment had on patient's outcomes measured by patient-reported outcome measures (PROMS) and patient satisfaction.
View Article and Find Full Text PDFJBI Evid Synth
January 2025
Office of Institutional Effectiveness, Touro University Nevada, Henderson, NV, USA.
Objective: The objective of this review is to evaluate the effect of cochlear implants on cognitive function in pediatric patients with hearing loss.
Introduction: Cognitive impairments have been reported in children with hearing loss. This is supported by the auditory scaffolding hypothesis, which describes sound as the basis for processing sequential information.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!