Purpose: Identify associations between preoperative radiographic measurements and clinical findings of zygomatic arch fractures and postoperative radiographic measurements. Based on those findings, propose a comprehensive treatment algorithm for the solitary zygomatic arch fracture and combined zygomatic arch-zygomatic complex fracture.
Methods: Retrospective cohort study with patients referred to our department for zygomatic arch fractures between 2013 and 2018. Data analyzed included patient demographics, clinical evaluation, and radiographic information. Predictor variables were preoperative morphometric measurements: the initial latero-lateral (LL) defect was determined by the difference between the preoperative LL distances of the fractured and the healthy arches, LL distance was measured from the midsagittal plane in the cranium to the inner cortex of the most displaced arch segment, initial arch coronoid distances were measured from the medial part of the most dislocated arch fragment to the lateral aspect of the coronoid, and the anterior-posterior telescoping was measured as the distance between the 2 points in the arch that lost continuity and overlapped as a result of the fracture. The outcome was defined as the residual defect. It was calculated as the ratio between the postoperative remaining LL distance and the initial LL defect.
Results: A total of 179 cases were enrolled, all involving head residual defects. Statistical analysis was performed only on 149 medially displaced fractures. Results show that an initial LL defect larger than 3.5 mm has an 86.3% chance of remaining with a better residual defect (<84.1%), P = .001. Cases with antero-posterior (AP) telescoping > 1.45 mm showed a 72.4% chance of remaining with a poor residual defect >84% (P = .003). Arch-coronoid initial distance showed little effect on the chance of remaining with a large remining defect (P = .417, CI = 95%) CONCLUSION: Based on our results, we found that morphometric measurements can be used to predict the reduction results and can assist the clinician in choosing the optimal reduction method and thus increasing the success rate.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.joms.2022.04.001 | DOI Listing |
Int J Periodontics Restorative Dent
January 2025
Purpose: The study aimed to compare the short-term outcomes (3.7±0.4yrs) of full-arch immediately loaded fixed maxillary prostheses supported by conventional and unilateral single zygomatic implants versus those supported by conventional and bilateral single zygomatic implants.
View Article and Find Full Text PDFObjective: Evaluate the feasibility of the midface degloving approach (MDA) in total maxillectomy without orbital exenteration (TMWOE) and reconstruction for sino-nasal neoplasms.
Study Design: Retrospective case series.
Setting: Tertiary referral center.
J Stomatol Oral Maxillofac Surg
January 2025
Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, PR China; National Engineering Laboratory for Digital and Material Technology of Stomatology, PR China; Beijing Key Laboratory of Digital Stomatology, PR China; National Clinical Research Center for Oral Diseases, Beijing, PR China. Electronic address:
Objective: To establish an automatic reduction method for unilateral zygomatic fractures based on Iterative Closes Point (ICP) algorithm.
Material And Methods: 60 patients with unilateral type B zygomatic fractures were included. After acquiring CT images, zygomatic fragments were segmented using self-developed software MICSys.
J Craniomaxillofac Surg
December 2024
Department of Craniomaxillofacial Surgery, University Hospital Schleswig-Holstein Campus Kiel, 24105, Kiel, Germany. Electronic address:
The state-of-the-art approach to open reduction and fixation (ORIF) of zygoma fracture fragments is based on manual skills. Achieving high accuracy can be challenging. Our feasibility study on deceased body donors with artificial zygomatic fractures investigated whether virtual repositioning of the fractures and the use of customised 3D-printed titanium osteosynthesis plates was similar in accuracy to the conventional manual procedure, and whether the method was applicable in a clinical setting.
View Article and Find Full Text PDFJ Craniofac Surg
October 2024
Department of Maxillofacial Surgery, Plastic Surgery Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing.
Objective: Pre-bent titanium plates are widely used for internal fixation in L-shaped zygomatic reduction. The aim is to evaluate the effect of pre-bent Z-shaped titanium plate on the narrowing of the zygomatic arch in L-shaped reduction malarplasty.
Methods: Thirty cosmetic female patients were selected and scanned using computed tomography (CT).