A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A comparative study of Cd(ii) adsorption on calcined raw attapulgite and calcined aluminium hydroxide-modified attapulgites in aqueous solution. | LitMetric

In this study, raw attapulgite and two aluminium hydroxide-modified attapulgites prepared using different aluminium salts were calcined at 600 °C to successfully prepare three novel adsorbents (C-ATP, C-ATP-SO and C-ATP-Cl). The three adsorbents were characterized by transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), Brunauer-Emmett-Teller (BET) analysis and X-ray photoelectron spectroscopy (XPS). Batch experiments revealed that the Cd(ii) adsorption capacity of the three adsorbents increased with increasing pH, increasing the initial concentration of Cd(ii) in solution, and with longer adsorption times. The order of adsorption capacity was always C-ATP > C-ATP-Cl > C-ATP-SO . C-ATP and C-ATP-Cl were better described by the Langmuir model, while C-ATP-SO was better described by the Freundlich model. The three adsorbents reached adsorption equilibrium within 2 h, and all followed pseudo-second order kinetics. The adsorption of Cd(ii) onto the three adsorbents was physisorption, as suggested by the calculated thermodynamic parameters. Although the adsorption of Cd(ii) on C-ATP and C-ATP-Cl was exothermic, the adsorption on C-ATP-SO was endothermic. Ion exchange and cadmium precipitation were the primary mechanisms of cadmium adsorption on the three adsorbents analysed by XPS. The presence of SO in C-ATP-SO may result in weaker binding of Cd(ii) by the adsorbent than C-ATP-Cl.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9074160PMC
http://dx.doi.org/10.1039/d2ra00720gDOI Listing

Publication Analysis

Top Keywords

three adsorbents
20
c-atp c-atp-cl
12
adsorption
9
cdii adsorption
8
raw attapulgite
8
aluminium hydroxide-modified
8
hydroxide-modified attapulgites
8
adsorption capacity
8
better described
8
adsorption cdii
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!