Objectives: To assess the clinical and radiological outcomes after ACDF with 3D printed cellular titanium cages filled with bone marrow and to compare the clinical and radiological results with the current scientific literature.

Methods: ACDF was performed monosegmentally under standardized conditions. X-rays were analyzed to determine the range of motion, fusion rates, and subsidence preoperatively and 3 and 12 months postoperatively. Clinical outcome measurements included neck disability index (NDI), visual analogue scale (VAS) for brachialgia and cervicalgia, and patient satisfaction.

Results: 18 patients were included in the study. The mean RoM decreased from 7.7° ± 2.6 preoperatively to 1.7° ± 1.1° after 3 months and 1.8° ± 1.2° 12 months after surgery. The fusion rates were at 94.4% after 3 and 12 months. The mean subsidence was 0.9 mm ± 0.5 mm 3 months postoperatively and 1.1 mm ± 0.5 mm 12 months after surgery. The mean NDI improved significantly from preoperatively to 12 months postoperatively (34.6 ± 6.2 and 3.4 ± 4.1, respectively). The VAS-neck also showed a large improvement from 5.8 ± 2.2 before and 1.3 ± 1.4 12 months after surgery, as did the VAS-arm (6.4 ± 1.5 and 0.9 ± 1.6, respectively). Patient satisfaction was high throughout the follow-up period.

Conclusion: ACDF with a 3D printed titanium cage resulted in fast fusion without pathological subsidence. In comparison to other cage materials such as PEEK, the 3D printed titanium cage was noninferior in regard to its fusion rate and clinical results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9071886PMC
http://dx.doi.org/10.1155/2022/6339910DOI Listing

Publication Analysis

Top Keywords

titanium cage
12
months postoperatively
12
months surgery
12
printed cellular
8
cellular titanium
8
bone marrow
8
clinical radiological
8
acdf printed
8
fusion rates
8
months
8

Similar Publications

3D printed titanium banana interbody cages versus titanium-coated PEEK bullet cages for TLIF.

Clin Neurol Neurosurg

January 2025

Department of Neurosurgery, The Ohio State University, 410 W 10th Ave, Columbus, OH 43210, United States.

Introduction: Lumbar degenerative spinal disease is a common, major cause of pain and disability. Titanium and polyetheretherketone (PEEK) are popular materials for interbody implants although evidence is mixed on which material is superior in terms of fusion and subsidence. The purpose of this study was to evaluate the clinical outcome of 3D printed titanium (3DPT) cages in patients undergoing TLIFs, as well as complication profiles based on widely used outcome metrics and reoperation events.

View Article and Find Full Text PDF

This study analyzes the risk factors related to the complications of anterior thoracolumbar tuberculosis in adults and to provide clinical reference. A total of 98 adult patients with thoracolumbar tuberculosis undergoing anterior surgery in our hospital from February 2020 to December 2023 were selected, and the clinical data and postoperative complications were collected. The clinical characteristics were analyzed, and the risk factors related to surgical complications were analyzed by univariate analysis and multi-factor logistic regression model.

View Article and Find Full Text PDF
Article Synopsis
  • Cage subsidence can negatively affect lumbar fusion procedures, with material selection (PEEK vs. 3D-Ti) influencing this issue; the study aims to compare their subsidence rates.
  • The systematic search reviewed 265 patients from three high-quality studies, focusing on cage subsidence and classified subsidence rates using a specific method.
  • Results indicated that 3D-Ti cages have a significantly lower rate of subsidence compared to PEEK cages, with less severe subsidence and better overall performance.
View Article and Find Full Text PDF

Background: Anterior cervical corpectomy and fusion (ACCF) is a standard surgical procedure for cervical spondylosis with spinal cord compression (CSWSCC), especially in patients with intensity on T2-weighted imaging high signal (T2WIHS). The titanium mesh cage (TMC) utilized in this procedure is essential in stabilizing the spine; however, the optimal slotting width of the TMC remains unclear.

Objective: This study aimed to investigate the impact of TMC slotting width on the clinical and radiological outcomes of ACCF in patients with spinal cord compression type cervical spondylosis with intensity on T2WIHS (CST2WIHS).

View Article and Find Full Text PDF

Objective: To explore clinical effect of Zero-profile intervertebral fusion with cage-titanium plate in treating multilevel cervical spondylotic myelopathy.

Methods: From January 2016 to January 2020, 107 patients with multisegmental cervical spondylotic myelopathy treated by surgery were retrospectively analyzed and divided into Hybrid group and control group according to different surgical methods. There were 54 patients in Hybrid group, including 42 males and 12 females, aged from 33 to 77 years old with an average of (57.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!