AI Article Synopsis

  • * The prevalence of AS increases significantly with age, from 0.2% in those aged 50-59 to nearly 10% in those aged 80-89.
  • * The case of a 78-year-old man with severe AS illustrates how ultrasonic aortic valve decalcification can effectively lower pressure gradients across the valve, serving as a valuable alternative for patients with small aortic annuli when traditional surgery is not feasible.

Article Abstract

Aortic stenosis (AS) - a constantly progressing disease characterized by thickening and calcification of leaflets of the valve, which leads to obstruction of the blood outflow from the left ventricular (LV), inadequate cardiac output, heart failure, and even sudden death. Prevalence of stenosis consistently increases with age, 0.2% incidence observes in the 50-59 year cohort of patients and almost 10% in patients from the 80-89 year cohort. We report the case of a 78-year-old man who presented with severe aortic valve stenosis. Since conventional valve replacement was problematic because of a small annular diameter we performed ultrasonic aortic valve decalcification. As a result, the systolic pressure gradient across the aortic valve decreased from 106 mm Hg to 22 mm Hg. Our case demonstrated that even in modern era ultrasonic aortic valve decalcification can be an effective option for restoration of mobility of the aortic valve cusps. We advocate the use of it for elderly patients with small aortic annulus in which surgical or transcatheter valve replacement, valve reconstruction could be extremely difficult or unavailable and consider ultrasonic valve decalcification as an additional tool in cardiac surgeon's hands.

Download full-text PDF

Source

Publication Analysis

Top Keywords

aortic valve
24
valve decalcification
12
valve
11
aortic
8
modern era
8
year cohort
8
valve replacement
8
ultrasonic aortic
8
ultrasonic
4
ultrasonic decalcification
4

Similar Publications

Percutaneous valve implantation or surgical replacement with mechanical or biological valves are standard therapies for severe valvular heart diseases. Prosthetic valve thrombosis, though rare, is a serious complication, particularly with mechanical prostheses. This study aimed to investigate the predictive value of platelet volume parameters, including mean platelet volume (MPV), platelet distribution width (PDW), and platelet-large cell ratio (P-LCR), for valvular thrombosis risk in patients undergoing valve replacement therapy.

View Article and Find Full Text PDF

Subvalvular aortic stenosis typically manifests at a young age and rarely presents in adulthood. It may cause left ventricular outflow tract stenosis, which requires surgical treatment in severe cases. The coexistence of discrete subvalvular aortic stenosis and quadricuspid aortic valve is a highly unusual finding.

View Article and Find Full Text PDF

The VACTERL (vertebral defects, anal atresia, cardiac defects, tracheoesophageal fistula, renal anomalies, and limb abnormalities) association represents an enigmatic syndrome requiring further study. This report describes a full-term neonate born to a multiparous woman who was found, upon further examination, to have multiple congenital abnormalities, including a bicuspid aortic valve, patent foramen ovale, tracheoesophageal fistula (TEF), asymmetric crying facies, microphallus, and a single inguinal testis. The discussion explores environmental and genetic factors that may contribute to this association, as well as similar conditions, such as CHARGE (coloboma, heart defects, choanal atresia, growth retardation, genital abnormalities, and ear abnormalities) syndrome.

View Article and Find Full Text PDF

The Y incision and roof technique for aortic valve replacement enable implantation of a large prosthetic valve and extensive enlargement of the sinotubular junction. Surgeons have been reluctant to adopt a minimally invasive approach for this procedure because of its complexity and risk. The Stonehenge technique was designed to achieve an ideal surgical view of the aortic root through a small right thoracotomy.

View Article and Find Full Text PDF

Valve-sparing aortic root replacements have acceptable reintervention rates in patients with failed pulmonary autografts after a Ross procedure. In our 50-year-old patient with post-Ross valve-sparing aortic root replacement, we report preoperative and postoperative 4-dimensional flow magnetic resonance imaging capturing changes in peak systolic velocity, 3-dimensional systolic flow profiles, and aortic wall shear stress that may predict a decreased risk of aortic dilation, a common complication in repeated Ross procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!