Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Symptomatic femoropopliteal occlusive disease has been increasingly treated using endovascular methods. However, restenosis, especially after implantation of permanent metallic stents, has remained common. To date, resorbable scaffolds have failed to achieve sufficient radial strength to enable the successful treatment of long, mobile, peripheral arteries. In the present nonsurvival, large animal experiment, a novel device consisting of multiple, short, serial, balloon-expandable, bioresorbable scaffolds was deployed in arteries subjected to supraphysiologic deformation. Compared with native vessels, the scaffolded arteries continued to bend (113° ± 19° vs 110° ± 20°; = .10) and shorten (15% ± 15% vs 20% ± 14%; = .16), unencumbered by the placement of the investigational device. The mean luminal diameter of the scaffolded arteries was preserved without kinks or occlusions in exaggerated flexion (4.7 ± 0.7 vs 4.7 ± 0.5 mm in extension vs flexion; = .80). Arterial deformation was borne by shortening of the interscaffold spaces (2.2 ± 0.8 mm vs 1.9 ± 0.7 mm in extension vs flexion; < .01) and the scaffolds themselves (10.7 ± 1.4 mm vs 9.9 ± 1.1 mm in extension vs flexion; < .01). The results from the present study challenge the perceived limitations of balloon-expandable devices implanted in peripheral mobile arteries. We have presented a bioresorbable scaffold that combines sufficient radial strength to preserve the mean luminal diameter with movement and the flexibility to accommodate femoropopliteal deformation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9065303 | PMC |
http://dx.doi.org/10.1016/j.jvssci.2022.03.002 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!