Ethylenediaminetetraacetic acid (EDTA) has been widely used as an effective reagent for removal of lead from soil because of its high lead extraction efficiency caused by the high thermodynamic stability of the Pb(ii)-EDTA complex. In this study, EDTA was used as a lixiviant for recovery of lead from residues (matte and slag) of secondary lead smelter plants. The residues were composed mainly of iron (34-66 wt%) and lead (7-11 wt%). Leaching parameters (EDTA concentration, pH, temperature, liquid-to-solid ratio and leaching time) were optimized. The optimum leaching efficiency was achieved when leached for 1 h at room temperature using 0.05 mol L EDTA at a liquid-to-solid ratio of 5 mL g. At such conditions, 72 to 80% of lead and less than 1% of iron were leached from both matte and slag. The high selectivity towards lead with minimal co-dissolution of iron is a major advantage since it reduces the chemical consumption and simplifies the downstream processes. Although the stability constants of the complexes Fe(iii)-EDTA, Fe(ii)-EDTA and Pb-EDTA are all large (log 25.1, 14.33 and 18.04, respectively), the leaching of iron was most likely limited by its presence in insoluble phases such as iron oxides, sulfides and silicates in the residues. 100% leaching of lead was achieved by a multi-step leaching process where the leaching residues were contacted three times by a fresh EDTA solution. To recover EDTA, first iron was precipitated as iron hydroxide by raising the pH of pregnant leach solution (PLS) above 12.6 using sodium hydroxide, followed by precipitation of lead as lead sulfide by adding ammonium sulfide. The recovered EDTA was successfully reused two times for leaching without significant changes in leaching yields.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9057912 | PMC |
http://dx.doi.org/10.1039/d0ra08517k | DOI Listing |
Head Neck
January 2025
Department of Otolaryngology, Head and Neck Surgery, Princess Alexandra Hospital, Queensland Skull Base Unit, Brisbane, Queensland, Australia.
Background: Standardized surgical approaches to advanced pre-auricular cutaneous squamous cell carcinomas (cSCC) are lacking.
Methods: Fifty-four patients who underwent lateral temporal bone resection (LTBR) for pre-auricular cSCC were grouped into "Levels" of increasing disease spread. Surgical approaches to achieve negative-margin resection were designed for each Level and replicated on cadaveric specimens.
J Obstet Gynaecol Res
February 2025
Sleep Center, Kuwamizu Hospital, Kumamoto, Japan.
Background: Pregnancy-related anatomic, physiologic, and hormonal factors can occur at different stages of pregnancy and affect sleep disturbances. The relationship between sleep problems during pregnancy and postpartum depressive symptoms as well as neonatal condition at delivery have not been well described. This study hypothesized that sleep problems are associated with postpartum depressive symptoms and adverse neonatal outcomes at delivery.
View Article and Find Full Text PDFAim: To discuss inter-organisational collaboration in the context of the successful COVID-19 vaccination programme in North Central London (NCL).
Design: An action research study in 2023-2024.
Methods: Six action research cycles used mixed qualitative methods.
Microsurgery
January 2025
Service de Chirurgie Plastique et Reconstructrice, Hôpital européen Georges-Pompidou, Paris, France.
Objective: The optimal method for maintaining intraoperative blood pressure during microsurgical procedures remains controversial. While intravenous fluid administration is essential, overfilling can lead to complications. Vasopressor agents are used cautiously due to their vasoconstrictive effects, which could potentially lead to flap failure.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Chemistry, Faculty of Science, Hokkaido University, Sapporo, Hokkaido, Japan.
Background: The use of iodinated contrast-enhancing agents in computed tomography (CT) improves the visualization of relevant structures for radiotherapy treatment planning (RTP). However, it can lead to dose calculation errors by incorrectly converting a CT number to electron density.
Purpose: This study aimed to propose an algorithm for deriving virtual non-contrast (VNC) electron density from dual-energy CT (DECT) data.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!