Statement Of Problem: Even though polyetheretherketone (PEEK) has become popular for various prosthetic indications, a standard adhesive protocol to bond the PEEK to titanium bases has not been yet established. How the heat-pressing technique performs in this respect is also not clear.
Purpose: The purpose of this in vitro study was to investigate the effect of an adhesive system-cement combination, the heat-pressing technique, and thermomechanical aging on the retention force between titanium bases and PEEK specimens.
Material And Methods: Sixty 9×11×20-mm PEEK specimens with a titanium base slot integrated into the design were milled to simulate an implant-supported PEEK framework for a cantilevered fixed prosthesis. The specimens were assigned to 8 groups (n=10) according to the titanium base primer (MKZ or Monobond) and resin cement (DTK or Multilink hybrid) used and with or without thermomechanical aging. Twenty PEEK specimens were directly heat-pressed on titanium bases, and half of the specimens were not subjected to thermomechanical aging (n=10). For nonaged groups, the PEEK specimen complex was tightened to an implant analog and secured on a custom-made pull-off device. Retention forces were measured by using the pull-off tensile test in a universal testing machine, and the maximum tensile bond strength (MPa) was calculated. The aged groups were subjected to 5000 cycles of thermal aging (5 °C to 55 °C), and the specimens were clamped to load the extension (cantilever) for 1 200 000 cycles with 120 N and 200 N at 1.5-Hz frequency. After aging, the pull-off test was performed for those specimens that survived thermomechanical aging. A nonparametric Kruskal-Wallis test was used to determine whether there was a difference among the groups, followed by pairwise Wilcoxon rank tests with Bonferroni correction. The Wilcoxon rank test was used to analyze the effect of thermomechanical aging in each adhesive system-cement or heat-press group (α=.05 for all tests).
Results: None of the specimens failed during cyclic loading. According to the Kruskal-Wallis test, the effect of the PEEK-Ti base bonding technique on the retention force in the nonaged (P=.019) and thermomechanically aged groups was significant (P=.010). In the nonaged groups, the heat-pressing technique resulted in a higher retention force than when the specimens were bonded by using the Monobond-Multilink hybrid combination (P=.031). Thermomechanical aging did not significantly affect the results (P>.241). All failures were adhesive, with cement remaining only on the Ti-bases.
Conclusions: All bonding protocols tested resulted in a stable bond between PEEK and Ti-bases, as all specimens survived thermomechanical aging. The heat-pressing technique resulted in mean bond strength values similar to those obtained with the tested adhesive system-cement combinations with 1 exception; the nonaged heat-pressed groups presented higher bond strength than the Monobond-Multilink hybrid combination. Failure types indicated that the weaker bond was between the PEEK and the cements tested rather than between the titanium base and the cements, regardless of the adhesive system-cement combination.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2022.03.026 | DOI Listing |
J Dent
January 2025
Senior Research and Teaching Assistant, Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich 8032, Switzerland. Electronic address:
Objectives: A new abutment-free implant connection allows for direct screwing of FDPs on implants to avoid complications caused by cement rests or screw loosening, which may affect to screw torque and load distribution. The objective of this study was to test the initial (Fi) and final failure (Ff) loads and torque changes of abutment-free monolithic zirconia CAD-CAM fixed dental prostheses (FDPs) compared to titanium FDPs on different abutment designs.
Methods: Three-unit screw-retained FDPs (n = 50) on two implants (n = 100) were divided into groups (n = 10) based on the implant-abutment connection and material of the supra-structure: (1) abutment-free monolithic CAD-CAM zirconia FDP (Abut-free-Zr), (2) abutment-free veneered titanium FDPs (Abut-free-Ti), (3) monolithic zirconia FDPs with titanium base abutments (Zr-Ti-Base), (4) monolithic zirconia FDPs on multi-unit abutments (Zr-MU), (5) veneered titanium FDP on multi-unit abutments (Ti-MU).
BMC Oral Health
December 2024
Department of Conservative Dentistry, Faculty of Dentistry, Minia University, Minia, Egypt.
Objectives: To compare the mechanical performance of partially replaced (repaired) intra-coronal restorations to totally replaced ones in root canal-treated teeth.
Methods: Thirty maxillary second premolars were selected according to strict criteria, mounted on moulds, and had mesio-occluso-distal (MOD) cavities prepared. Resin composite restorative material was used to perform the initial restoration, followed by aging procedures using thermo-mechanical cycling fatigue to replicate six months of intraoral aging.
J Esthet Restor Dent
December 2024
Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea.
Objectives: To evaluate the complementary mechanical properties of dental ceramics using edge chipping resistance (Rea) and flexural strength before and after thermomechanical aging.
Material And Methods: Computer-aided design and computer-aided manufacturing of ceramic materials, including zirconia (ZR), lithium disilicate (LS2), and resin nanoceramics (RNC), were evaluated. Specimens for flexural strength testing were fabricated with dimensions of 3 × 4 × 25 mm, with 30 specimens per group.
J Prosthodont
December 2024
Dental Research Center, Dentistry Research Institute, Department of Prosthodontics, Tehran University of Medical Sciences, Tehran, Iran.
Purpose: Metal-ceramic screw-retained implant restorations persist as a fundamental choice in specific clinical scenarios. Little is known about the effects of fabrication steps and aging on their structural properties. This study aimed to investigate how laboratory fabrication procedures and thermomechanical loading affect the structural properties of screw-retained metal-ceramic implant restorations.
View Article and Find Full Text PDFJ Prosthodont
December 2024
Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
Purpose: To evaluate the effect of material type on dimensional stability, occlusal surface wear, fracture resistance, and failure behavior of resin-based onlay restorations.