Diagnostic accuracy of red blood cell distribution width for neonatal sepsis.

Minerva Pediatr (Torino)

School of Public Health, Department of Occupational Health and Environmental Health, Anhui Medical University, Hefei, Anhui, China -

Published: April 2022

AI Article Synopsis

  • The meta-analysis aimed to investigate the relationship between red blood cell distribution width (RDW) and neonatal sepsis (NS), a condition affecting newborns, as there was no clear consensus on this topic.
  • After analyzing 15 studies with a total of 1,362 newborns, the results showed that RDW levels were significantly higher in newborns with sepsis compared to healthy controls.
  • The findings suggested that RDW is a cost-effective and reliable diagnostic biomarker for neonatal sepsis, demonstrating good sensitivity and specificity.

Article Abstract

Introduction: Red blood cell distribution width (RDW) is a biomarker for the diagnosis and prognosis of many diseases. However, the relevance between RDW and neonatal sepsis (NS) have not reached a consensus yet; the perform of RDW in the diagnosis of neonatal sepsis is still not clear. The aim of this meta-analysis was to estimate the significance of RDW in neonatal sepsis and the perform of RDW in diagnosis of neonatal sepsis.

Evidence Acquisition: We used Pubmed, Embase, Web of science, CNKI and Google academic database to find all articles that met the inclusion criteria until July 1, 2020.

Evidence Synthesis: Fifteen eligible studies involving 1362 newborns were included in the meta-analysis after two independent investigators read the title, abstract and full text in detail. The pooled result of this meta-analysis showed that RDW was significantly higher in the NS group than in the control group (WMD=3.224; 95%CI: 2.359-4.090, P<0.001). In addition, the overall pooled sensitivity, specificity, PLR, NLR and DOR were 0.88 (95%CI:0.66-0.96), 0.90 (95%CI:0.65-0.98), 9.2 (95%CI:2.1-40.3), 0.14(95%CI:0.04-0.43) and 66.9 (95%CI:8.73-513.26), respectively. The area under the SROC curve (AUC) was 0.95 (95%CI:0.93-0.96).

Conclusions: The meta-analysis demonstrated that newborns with sepsis had an elevated RDW level than healthy controls. RDW levels have significant correlated with neonatal sepsis; and RDW can be used as a cheap and satisfactory diagnostic biomarker for neonatal sepsis with a relatively high performance.

Download full-text PDF

Source
http://dx.doi.org/10.23736/S2724-5276.21.06149-1DOI Listing

Publication Analysis

Top Keywords

neonatal sepsis
16
red blood
8
blood cell
8
cell distribution
8
distribution width
8
rdw neonatal
8
perform rdw
8
rdw diagnosis
8
diagnosis neonatal
8
rdw
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!