Background And Purpose: Proton therapy (PT) can reduce side effects for paediatric cranial malignancies. Despite the high number of paediatric patients treated with PT, radiation induced risk factors for second primary cancer (SPC) in out-of-field organs are unknown. This study estimated lifetime attributable risk (LAR) of SPC as a function of age and sex for out-of-field organs following passive scattering and scanning beam PT in paediatric brain tumours.

Materials And Methods: Measured neutron dose equivalent spectra for scattered and scanning PT were sourced from literature. The physical distance of 12 measured organs from paediatric CT dataset-based phantoms (5, 9 and 13 years-of-age) were applied to Schneider et al.'s analytical model using MATLAB (R2020B) to calculate the organ-specific LAR of SPC.

Results: Scanning beam PT demonstrated smaller LAR (per 10,000 person years) of SPC compared to scattering. This was prominent for more radiosensitive organs, including the lung (320 vs 50), breast (1000 vs 150) and thyroid (350 vs 75), but not for all (i.e., rectum and reproductive organs were <10). For most organs, LAR was highest for 5-year-old females (i.e., breast LAR was 1,000 higher than for 13-year-olds), however, outliers existed for distal organs (i.e., stomach and lung).

Conclusion: There was large variation in LAR estimates of out-of-field organs based on measured neutron dose equivalents. Younger female cranial paediatric patients were found at higher risk compared to males, especially for passive scattering PT. Not all organs had improved LAR using scanning beam PT for younger age groups.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2022.04.027DOI Listing

Publication Analysis

Top Keywords

out-of-field organs
12
lifetime attributable
8
attributable risk
8
radiation induced
8
second primary
8
primary cancer
8
scattering scanning
8
proton therapy
8
organs paediatric
8
paediatric patients
8

Similar Publications

The estimation of peripheral dose (PD) is vital in cancer patients with long life expectancy. Assessment of PD to radiosensitive organs is important to determine the possible risk of late effects. An attempt has been made to assess the peripheral dose using optically stimulated luminescence dosimeter (OSLD) with megavoltage photon beams as a function of field size, depth, energy, and distance from the field edge.

View Article and Find Full Text PDF

Set-up errors are a problem for pre-clinical irradiators that lack imaging capabilities. The aim of this study was to investigate the impact of the potential set-up errors on the dose distribution for a mouse with a xenographic tumour irradiated with a standard Cs-137 cell irradiator equipped with an in-house lead collimator with 10 mm diameter apertures. The EGSnrc Monte-Carlo (MC) code was used to simulate the potential errors caused by displacements of the mouse in the irradiation setup.

View Article and Find Full Text PDF

Background: The biological effects and clinical consequences of out-of-field radiation in peripheral organs can be difficult to determine, especially for low doses (0.1 Gy-1 Gy). In recent years, Monte Carlo (MC) methods have been proposed to more accurately predict nontarget doses.

View Article and Find Full Text PDF

Purpose: To propose a methodology for integrating the out-of-field and imaging doses to the in-field dose received by radiotherapy (RT) patients. In addition, the impact of considering the total dose in planning and radiation-induced second malignancies (RISM) risk assessment will be evaluated in several scenarios comprising photon and proton treatments.

Methods: The total dose is the voxel-wise sum of the doses from the different radiation sources (accounting for the radiobiological effectiveness) produced during the whole RT chain.

View Article and Find Full Text PDF

Targeted microwave ablation (TMA) is a novel focal therapy modality for prostate cancer (PC). TMA-HK is the first phase 2 trial investigating the efficacy and functional outcomes of transperineal TMA (NCT04113811) in 30 men with low- or intermediate-risk PC. TMA was performed transperineally with magnetic resonance imaging (MRI)-ultrasound fusion guidance and organ-based tracking.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!