caliPER: A software for blood-free parametric Patlak mapping using PET/MRI input function.

Neuroimage

Lawson Health Research Institute, London, Ontario, Canada; Department of Medical Biophysics, Western University, London, Ontario, Canada; Department of Neurology and Neurosurgery, Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada. Electronic address:

Published: August 2022

Routine clinical use of absolute PET quantification techniques is limited by the need for serial arterial blood sampling for input function and more importantly by the lack of automated pharmacokinetic analysis tools that can be readily implemented in clinic with minimal effort. PET/MRI provides the ability for absolute quantification of PET probes without the need for serial arterial blood sampling using image-derived input functions (IDIFs). Here we introduce caliPER, a modular and scalable software for simplified pharmacokinetic modeling of PET probes with irreversible uptake or binding based on PET/MR IDIFs and Patlak Plot analysis. caliPER generates regional values or parametric maps of net influx rate (K) using reconstructed dynamic PET images and anatomical MRI aligned to PET for IDIF vessel delineation. We evaluated the performance of caliPER for blood-free region-based and pixel-wise Patlak analyses of [F] FDG by comparing caliPER IDIF to serial arterial blood input functions and its application in imaging brain glucose hypometabolism in Frontotemporal dementia. IDIFs corrected for partial volume errors including spill-out and spill-in effects were similar to arterial blood input functions with a general bias of around 6-8%, even for arteries <5 mm. The K and cerebral metabolic rate of glucose estimated using caliPER IDIF were similar to estimates using arterial blood sampling (<2%) and within limits of whole brain values reported in literature. Overall, caliPER is a promising tool for irreversible PET tracer quantification and can simplify the ability to perform parametric analysis in clinical settings without the need for blood sampling.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neuroimage.2022.119261DOI Listing

Publication Analysis

Top Keywords

arterial blood
16
serial arterial
12
input functions
12
input function
8
blood sampling
8
pet probes
8
blood input
8
caliper
5
input
5
pet
5

Similar Publications

External delay and dispersion correction of automatically sampled arterial blood with dual flow rates.

Biomed Phys Eng Express

January 2025

Brain Health Imaging Centre, Centre for Addiction and Mental Health, B68-250 College St, Toronto, Ontario, M5T 1R8, CANADA.

Objective: Arterial sampling for PET imaging often involves continuously measuring the radiotracer activity concentration in blood using an automatic blood sampling system (ABSS). We proposed and validated an external delay and dispersion correction procedure needed when a change in flow rate occurs during data acquisition. We also measured the external dispersion constant of [11C]CURB, [18F]FDG, [18F]FEPPA, and [18F]SynVesT-1.

View Article and Find Full Text PDF

Inflammatory responses and lipid metabolism disorders are key components in the development of coronary artery disease and contribute to no-reflow after coronary intervention. This study aimed to investigate the association between the neutrophil to high-density lipoprotein ratio (NHR) and no-reflow phenomenon in ST-segment elevation myocardial infarction (STEMI) patients after primary percutaneous coronary intervention (PPCI). This study enrolled 288 patients with STEMI from September 1st, 2022 to February 29th, 2024, in the Zhengzhou Central Hospital Affiliated to Zhengzhou University.

View Article and Find Full Text PDF

Associations of cathepsins with pulmonary arterial hypertension mediated by circulating metabolites: A Mendelian randomization study.

Medicine (Baltimore)

January 2025

National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, China.

The correlation between cathepsins and pulmonary arterial hypertension (PAH) is well-established, but the causative link between them remains uncertain. This study aimed to explore the causal role of circulating metabolites mediating cathepsins in PAH using Mendelian randomization (MR). A 2-sample 2-step MR method was used to identify causal relationship between cathepsins and PAH; causal relationship between circulating metabolites and PAH; and mediated effects of these circulating metabolites.

View Article and Find Full Text PDF

Chronic coronary artery disease (CAD) remains a significant global healthcare burden. Current risk assessment methods have notable limitations in early detection and risk stratification. Hence, there is an urgent need for innovative biomarkers that facilitate the premature CAD diagnosis, ultimately leading to reduction in associated morbidity and mortality rates.

View Article and Find Full Text PDF

This study assesses the effect of carotid sinus blockade applied with a local anesthetic on hemodynamic parameters during carotid endarterectomy (CEA) operations performed under general anesthesia. The medical records of patients who underwent CEA under general anesthesia between January 2020 and December 2022, were retrospectively reviewed. It was recorded whether the patients received carotid sinus block with 2 mL of 2% prilocaine.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!