Objectives: The aim of this study is to evaluate the effect of guide level on the accuracy of static computer-aided implant surgery (sCAIS) at post-extraction sockets and healed sites.
Materials And Methods: A total of 30 duplicate dental models, with 300 potential implant sites, were used. All the models were equally randomized into three groups: fully guided (FG, n = 100), partially guided (PG, n = 100), and free handed (FH, n = 100) surgeries. After implant placement, the mean global, horizontal, depth, and angular deviations between the virtually planned and actual implant positions were measured automatically by a Python script within software Blender.
Results: Both FG and PG surgeries showed significantly higher accuracy than FH surgery at post-extraction sockets and healed sites. In both sCAIS groups, there were nearly 50% more deviations from implants placed at sockets than those from delayed placement. For the immediate implant placement, the accuracy of sCAIS was significantly affected by the level of guidance. The FG group exhibited lower deviations than the PG group, with a significant difference in coronal global and horizontal deviations (p < .05). For the healed sites, two guided groups exhibited similar outcomes (p > .05).
Conclusions: sCAISs provide more accuracy than the free-handed approach in position transferring from planning to a model simulation. Full guidance can significantly increase the accuracy, especially at post-extraction sites.
Clinical Relevance: Guided protocols showed significantly higher accuracy than free-handed surgery regardless of implantation timing, but both had nearly 50% more deviations in immediate implant placement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00784-022-04512-y | DOI Listing |
BMC Oral Health
January 2025
4th Division, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, No. 22, Zhongguancun South Avenue, Haidian District, Beijing, 100081, People's Republic of China.
Background: The stability of soft and hard tissues surrounding the implant is not only a matter of aesthetics, but also affects the long-term stability of the implant. The present study was to explore the influence of buccal mucosa width/height (W/H) ratio, emergence profile and buccal bone width on peri-implant soft and hard tissue changes in the posterior region.
Methods: Fifty-eight posterior implant restoration cases were recruited in this study.
Oral Maxillofac Surg Clin North Am
January 2025
Desert Ridge Oral Surgery Institute, 20950 N Tatum Boulevard #200, Phoenix, AZ 85050, USA; Private Practice of Oral and Maxillofacial Surgery, Phoenix, AZ, USA; Banner University Medical Center, Department of Oral and Maxillofacial Surgery, University of Arizona, Phoenix, AZ, USA.
Guided zygomatic implant placement surgery has emerged as a promising solution for patients with severe maxillary bone loss, offering precise implant placement and predictable outcomes. This article provides a comprehensive review of the current state-of-the-art techniques, advantages, challenges, and future directions in guided zygomatic implant surgery.
View Article and Find Full Text PDFInt J Oral Maxillofac Surg
January 2025
Stomatological Hospital of Chongqing Medical University, Chongqing, China; Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China; Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China. Electronic address:
The retrospective study aimed to compare the space-maintaining effects of sticky bone (bone graft matrix enriched with injectable platelet-rich fibrin) and titanium mesh for bone augmentation in the aesthetic zone. Patients who underwent single implant placement and had type 2/4 alveolar bone defects (buccal bone wall loss is >50% of the expected implant length) were screened for inclusion in this study. The labial bone plate width was measured at 1, 3, and 5 mm below the apical implant platform on cone beam computed tomography images taken immediately and 6 months after surgery.
View Article and Find Full Text PDFJ Clin Med
December 2024
Anesthesiology and Operative Intensive Care, Faculty of Medicine, University of Augsburg, 86156 Augsburg, Germany.
Mediastinal mass syndrome represents a major threat to respiratory and cardiovascular integrity, with difficult evidence-based risk stratification for interdisciplinary management. We conducted a narrative review concerning risk stratification and difficult airway management of patients presenting with a large mediastinal mass. This is supplemented by a case report illustrating our individual approach for a patient presenting with a subtotal tracheal stenosis due to a large cyst of the thyroid gland.
View Article and Find Full Text PDFJ Clin Med
December 2024
Clinic for Masticatory Disorders and Dental Biomaterials, Center for Dental Medicine, University of Zurich, 8006 Zurich, Switzerland.
: Sinus lifting, a procedure to augment bone in the maxilla, may cause complications such as sinusitis due to impaired drainage. This study aimed to assess how sinus lifting impacts airflow in the sinus cavity, which is essential for patients undergoing dental implants. Using computational fluid dynamics (CFD), this research analyzed airflow changes after sinus floor elevation, offering insights into the aerodynamic consequences of the procedure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!