Unique microstructured nickel ammonium phosphate Ni(NH)(PO)·4HO and Ni(NH)(PO)·4HO/GF composite were successfully synthesized through the hydrothermal method with different graphene foam (GF) mass loading of 30, 60 and 90 mg as a positive electrode for asymmetric supercapacitors. The crystal structure, vibrational mode, texture and morphology of the samples were studied with X-ray diffraction (XRD), Raman spectroscopy, Brunauer-Emmett-Teller (BET) surface area analysis and scanning electron microscopy (SEM). The prepared materials were tested in both 3-and 2-electrode measurements using 6 M KOH electrolyte. The composite material Ni(NH)(PO)·4HO/60 mg exhibited a remarkable gravimetric capacity of 52 mA h g, higher than the 34 mA h g obtained for the Ni(NH)(PO)·4HO pristine sample, both at 0.5 A g. For the fabrication of the asymmetric device, activated carbon from pepper seed (ppAC) was used as a negative electrode while Ni(NH)(PO)·4HO/60 mg GF was adopted as the positive electrode. The Ni(NH)(PO)·4HO/60 mg GF//ppAC asymmetric device delivered a specific energy of 52 Wh kg with an equivalent specific power of 861 W kg at 1.0 A g within a potential range of 0.0-1.5 V. Moreover, the asymmetric device displayed a capacity retention of about 76% for over 10 000 cycles at a high specific current of 10.0 A g.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9052949 | PMC |
http://dx.doi.org/10.1039/d0ra02300k | DOI Listing |
Med Biol Eng Comput
January 2025
School of Biomedical Engineering, Shanghai Jiao Tong University, No.1954 Huashan Road, Shanghai, 200030, Shanghai, China.
Previous studies reported baseline state-dependent effects on neural and hemodynamic responses to transcranial ultrasound stimulation. However, due to neurovascular coupling, neither neural nor hemodynamic baseline alone can fully explain the ultrasound-induced responses. In this study, using a general linear model, we aimed to investigate the roles of both neural and hemodynamic baseline status as well as their interactions in ultrasound-induced responses.
View Article and Find Full Text PDFJ Am Chem Soc
January 2025
Materials Science and Engineering Division, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States.
Cu electrodeposition and the electrocatalysis of hydrogenation reactions thereupon involve significant interactions with adsorbed hydrogen. Electrochemical mass spectrometry (EC-MS) is used to explore the formation and decomposition of surface hydride on Cu(111) in 0.1 mol L HClO.
View Article and Find Full Text PDFExecutive functions, including working memory, are typically assessed clinically with neuropsychological instruments. In contrast, computerized tasks are used to test these cognitive functions in laboratory human and animal studies. Little is known of how neural activity captured by laboratory tasks relates to ability measured by clinical instruments and, by extension, clinical diagnoses of pathological conditions.
View Article and Find Full Text PDFSchizophr Res Cogn
June 2025
Shanghai Key Laboratory of Psychotic Disorders, Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200030, PR China.
Evidence suggests that attenuated mismatch negative (MMN) waves have a close link to auditory verbal hallucinations (AVH) and their clinical outcomes, especially impaired neural oscillations such as θ, β representing attentional control. In current study, thirty patients with schizophrenia and AVH (SZ) and twenty-nine healthy controls (HC) underwent multi-feature MMN paradigm measurements including frequency and duration deviant stimuli (fMMN and dMMN). Clinical symptoms and MMN paradigm were followed up among SZ group after 8-week treatment.
View Article and Find Full Text PDFCureus
December 2024
Department of Anaesthesiology, Seirei Hamamatsu General Hospital, Hamamatsu, JPN.
One-lung ventilation is commonly used in lateral open chest surgery; however, it can increase pulmonary vascular resistance, which negatively affects Fontan circulation. Nevertheless, one-lung ventilation has a positive indication in post-Fontan patients. It allows surgery with lateral minimally invasive thoracotomy, which does not require a median sternotomy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!